Service manual

B
A C D E F G SERVICE
30
tray (for access instructions see section E2). The socket is shown to the right and can be
identied by green wires.
Home Automation Operation:
Relay closed
The replace will start in a medium setting until it receives a signal from the remote con-
trol unit (up to 4 minutes). Once the remote has communicated with the replace it will
turn on and begin operating the replace thermostatically. The remote will use whatever
temperature the user has previously set and cannot be altered by the home automation
system. The replace will continue to operate while the relay is closed.
Note: If the replace cannot communicate with the remote controller within 10 minutes
of the relay contact closure then the replace will shut down and return to standby. The
remote controller is required to be operating within range of the replace for its safe
operation.
Relay open
If the replace was operating with a closed relay then upon opening the relay contacts
the replace will shut down and return the remote controller to its standby mode when
it next updates (up to 4 minutes). While the relay is open the replace will be in standby
mode and available for manual operation by the user.
END OF SECTION E
By the end of this section, you should have:
The appliance installed in the cavity
The appliance xed to the cavity base and wall lining
The appliance plugged into a mains electricity supply
The selected fuel bed installed and glass in place
The appliance gas supply attached and pressure tested with all other gas appli-
ances running
Checked that the appliance ignites reliably and safely at least three times