Service manual
B
A C D E F G SERVICE
30
tray (for access instructions see section E2). The socket is shown to the right and can be
identied by green wires.
Home Automation Operation:
Relay closed
The replace will start in a medium setting until it receives a signal from the remote con-
trol unit (up to 4 minutes). Once the remote has communicated with the replace it will
turn on and begin operating the replace thermostatically. The remote will use whatever
temperature the user has previously set and cannot be altered by the home automation
system. The replace will continue to operate while the relay is closed.
Note: If the replace cannot communicate with the remote controller within 10 minutes
of the relay contact closure then the replace will shut down and return to standby. The
remote controller is required to be operating within range of the replace for its safe
operation.
Relay open
If the replace was operating with a closed relay then upon opening the relay contacts
the replace will shut down and return the remote controller to its standby mode when
it next updates (up to 4 minutes). While the relay is open the replace will be in standby
mode and available for manual operation by the user.
END OF SECTION E
By the end of this section, you should have:
□ The appliance installed in the cavity
□ The appliance xed to the cavity base and wall lining
□ The appliance plugged into a mains electricity supply
□ The selected fuel bed installed and glass in place
□ The appliance gas supply attached and pressure tested with all other gas appli-
ances running
□ Checked that the appliance ignites reliably and safely at least three times