Service manual
B
A C D E F G SERVICE
44
S3 Checking Operating Pressure:
See section E14 of this manual.
S4 Cleaning the Log Set and Glass:
NEVER RUB THE FASCIA. The outside of the fascia’s must only be cleaned with a clean damp
cloth, dry o after cleaning. The high temp silver powder coating that is used on Escea fascia
parts contains certain amounts of aluminium that when rubbed too hard will oxidise leaving
a black smudge that cannot be removed. Always clean when cold.
This is a service procedure that will need to be carried out whenever soot builds up on
logs and/or inside of glass. If soot build up becomes excessive or regular then one of the
following actions may be required;
• Reset gas pressure, pressure may be too high;
• Reposition log set so that front edge of each log is just behind each row of holes in
burner top;
• Clear any blockage from primary air port of burner;
• Check ue tube is not damaged or disconnected.
For diagrams and further info on removing your fascia, reverse the steps found in section F.
• Remove fascia bottom panel by pulling it o the magnets that retain it to the re.
Remove the 2 screws holding the inner fascia, lift o the inner fascia by pulling the
base of the inner fascia out and lifting it up and o.
• Unscrew the side and top glass retainers and remove them. Take care that the glass
does not fall forwards at this stage.
• Lift out glass and place it carefully aside.
• Take out fuel bed and gently brush any soot from log with a soft hearth brush. The
burner tops can be vacuumed to remove any excess material.
• Clean the inside and outside of glass with normal glass cleaning products. Use a
CLEAN DRY cloth only. Stubborn marks may be cleaned with a ceramic glass cleaner.
• Replace in opposite order and test run heater.
S5 Servicing the Horizontal Powerue Wall Terminal
If the Horizontal Powerue Wall Terminal needs servicing, the fan can be accessed from
the outside of the installation.
Ensure the power to the Horizontal Powerue Wall Terminal is o by disconnecting the
power to the appliance inside. If the appliance has been running, allow the terminal to
cool before attempting to service it.
Undo the ten screws holding the outer cowl in place and pull the whole plate and cowl