Installation manual

630162_5EF5000InstallationGuideRemotion‐US
5.0 Wall cladding around fire:
5.1 The temperature of the wall directly above the heater will get hot and hence may discolour
paint finishes.
5.2 Some dark coloured exhaust stains may also become visible directly above the fire due to
exhaust. In most cases this can be cleaned off with water and a brush.
6.0 Minimum install height:
The fire has ventilation gaps behind the fascia at the top and bottom. These must not be
blocked, so ensure there is a gap of at least 1 1/2” between the bottom of the fascia and
anything below.
7.0 Types of Installation:
This appliance shall only be used in an open-air situation with natural ventilation, without
stagnant areas, where gas leakage and products of combustion are rapidly dispersed by
wind and natural convection.
Certain materials or items, when placed under or near the appliance, will be subjected to
radiant heat and could become damaged.
Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used
shall comply with one of the following:
- An enclosure with walls on all sides, but at least one permanent opening at
ground level and no overhead cover.