Use and Care Manual

Single-Multi way
1. Line (Hot)
2. Neutral
3. Ground
4. First load
5. Second load
Multi switch-single way
1. Line (Hot)
2. Neutral
3. Ground
4. First load
5. other switch
(regular switch or
this product )
Single-Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
Step 2
Identifying your wiring application
(most common):
NOTE: If the wiring in the wall box does not
resemble any of these congurations, consult an
electrician.
3
4
1
5
2
3
4
1
5
2
Cat. No. 2ATWWJKX-TWWR
Model: EEFPTL-ACRC-W
2.4G Wall Type Wireless Dimming & CCT Tunable Dimmer
1200W-120Vac, 60Hz, 1500W-277Vac, 50Hz
Only suitable for driver of 2.4G wireless CCT tunable LED fixtures produced by E E Systems Group, Inc.
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
To avoid fire, shock, or death; turn off power at circuit breaker or fuse and test that power is off before wiring
E E Systems Group, Inc.
12346 Valley Blvd, Suite A
El Monte, CA 91732 USA
Info@eesgi.com;
1-877-579-3889 Mon.-Fri. 10am-5pm PST
or servicing fixture!
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult an electrician.
WARNINGS AND CAUTIONS:
Use one dimmer in a 3- or 4-way circuit.The switch(es) will turn the light on at the brightness level selected at the dimmer.
Use this device only with copper or copper clad wire.
Lighting fixture and dimmer must be grounded.
Tools needed to install your Dimmer
Slotted / Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
Installing Dimmer by itself or with other devices
If installing Dimmer in a single device application, proceed
with the INSTALLING YOUR DIMMER section. If installing
Dimmer in a multi-device application, proceed as follows:
Your Dimmer includes three color options. The Dimmer
ships with the White frame attached. To change color of
frame, proceed as follows:
Changing the color of your Dimmer
Push in side at tab
to release
Line up tabs and
press in side to attach
Note: Move slider on dimmer and slider on change kit
to bottom of the slide bar prior to engaging.
MULTI-DEVICE APPLICATION:
NOTE: You only need to remove side sections if installing
with other dimmers or if it does not t in wall box – not
when installing with mechanical switches.
When installing more than one dimmer in the same
location, the side sections of the mounting strap must be
removed. Use pliers to carefully bend side sections back
and forth until they break off.
Bend back and
forth to remove side
section
Remove
all inner
side
sections
Do not
remove
outer
side
sections
WARNING: TO AVOID FIRE, SHOCK, OR
DEATH; TURN OFF POWER at circuit breaker or
fuse and test that power is off before wiring!
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Step 1
Two
Gang
More than
Cat. No.
Volts
Single
2 Devices
2ATWWJKX-TWWR
120 1200VA 1200VA 1200VA
277 1500VA 1500VA 1500VA
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Note: No derating is required in this mult-device installation
as referenced in the following chart.
MAXIMUM BULB WATTAGE:
The maximum number of loads per dimmer is based on the
sum of the load ratings. For example, one dimmer can carry
a maximum of 24pcs 50W LED fixtures when the voltage is
120Vac; when the voltage is 277Vac, a maximum of 30 can
be carried.
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
Step 4A
Step 3
Preparing wires:
Pull off pre-cut insulation from Dimmer leads.
Make sure that the ends of the wires from the wall
box are straight (cut if necessary) .
Remove 5/8" (1.6 cm) of insulation from each wire
in the wall box (shown).
For Single-Pole Application, go to Step 4A.
For 3-Way Application, go to Step 4B.
Strip Gage
5/8"
(1.6 cm)
Cut
(if necessary)
Strip 5/8"
(1.6 cm)
Insert wires
straight then twist
clockwise
Electrical Tape
Ground
Neutral
Black
Red
White
Red
This wire is used in 3-way installations only.
For single pole installations, do not remove this
insulating label.
Single-Pole Wiring Application:
Connect wires per WIRING DIAGRAM 1 (shown on
page 2) as follows:
Screwing wire nuts on clockwise ensures no bare
conductors showed below the wire connectors.
Secure each connector with electrical tape.
Step 4B
Single-Multi way Application:
NOTE:
Connect the ground wire of the fixture to the ground
wire in the line.
Connect the black wire of this product to the live wire
in the wire.
Connect the white wire of this product to the neutral
wire in the line.
Connect the red line marked with output to the load in
the line.
The remaining red lines are not connected
Connect wires per WIRING DIAGRAM 1 (shown on
page 2) as follows:
Screwing wire nuts on clockwise ensures no bare
conductors showed below the wire connectors.
Secure each connector with electrical tape.
NOTE:
Connect the ground wire of the fixture to the ground
wire in the line.
Connect the black wire of this product to the live wire
in the wire.
Connect the white wire of this product to the neutral
wire in the line.
Connect the red line marked with output to the all load
in the line.
The remaining red lines are not connected
3
4
1
2
Insert wires
straight then twist
clockwise
Electrical
Tape
Ground
Neutral
Black
Red
White
Red
This wire is used in 3-way installations only.
For single pole installations, do not remove this
insulating label.
Step 4C
Multi switch-single way Application:
This wire is used in 3-way installations only.
For single pole installations, do not remove this
insulating label.
Other switch
Connect wires per WIRING DIAGRAM 1 (shown on
page 2) as follows:
Screwing wire nuts on clockwise ensures no bare
conductors showed below the wire connectors.
Secure each connector with electrical tape.
NOTE:
Connect the ground wire of the fixture to the ground
wire in the line.
Connect the black wire of this product to the live wire
in the wire.
Connect the white wire of this product to the neutral
wire in the line.
Connect the red line marked with output to the load
in the line.
Connect the remaining red wire to another switch.
Insert wires
straight then twist
clockwise
Electrical Tape
Ground
Neutral
Black
Red
White
Red
IMPORTANT: When single control single pole and single control
multi-way, connect the load line to the red line of this product
whose label marked with “output”.
When multi control single way, connect the load line to the red
line of this product whose label marked with “output”, and
connect the other switch lineto another red line of this product.