Installation manual
36
embeds this setting in the Advanced installation scenario so you must select Advanced ? Fully customized installation
during the installation.
We highly recommend that you check all requirements before installation, especially if there are multiple workstations in
the network (on the Remote Install tab select the Computers tab, right-click the relevant client(s) and select Diagnostics
of Push Installation from the context menu).
ESET Remote Administrator 4.2
4.2.2 Configuring the environment for remote installation
Before installing ESET security products to network computers, the administrator should appropriately prepare the
environment to avoid installation failures.
The Network View section in Remote Install tab provides a customizable view for the network. There are two ways to
explore the network.
Console
The Console view provides standard NetBios search from the computer on which ERAC is installed. It shows all available
domains and workgroups which can be (un)checked in order to filter the view.
Server
The Server view provides more filtering options. Aside from the NetBios search, you can view computers in Active
Directory, existing ERA clients and also create your own, custom filters.
The custom filters include two items — Custom List and IP Search, both of which allow you to create your own groups
manually.
In the Custom list, you can add computers to a group either manually, by typing their names into the Computers in
group section, or by importing them from a .txt file. In both cases the computer names must be written one by one, as a
list.
The IP Search section allows you to create computer IP ranges and groups of computer IP ranges, where the IP range
serves as a filtering criterion.
NOTE: The Console/Server branches specify whether computers are browsed from ERAS or ERAC. We recommend taking
this into consideration if you are connecting to ERAS from a different network.
The Filter Options section provides two additional filtering options:
Unregistered computers — shows computers that are not listed in the current server database.
Clients with last connected warning — shows computers that are listed in the current server database and have
incurred the last connected warning.
After setting up all necessary conditions in the Network View and Filter Options sections, you can see a list of
workstations suitable for installation of a client solution on the right side of the window in the Computers tab. You can
run push installation diagnostics on computers that are found and displayed in the list by right-clicking on the selected
computers and selecting Diagnostics of Push Installation from the context menu. The diagnostics help you check
installation requirements and identify potential problems.










