Installation manual

IVX 20 System programming: an introduction
C.3
Accessing user station programming
Should a user forget his password or if an employee leaves the organization, this feature allows the
Installer or Administrator to enter a user's station programming and operate within it as if he were
the user. From the user’s station, input the Installer or Administrator password when the system
prompts for the user password.
Example: From station 105, entering 7 8 9 # or 4 5 6 # instead of the user password
(1 0 5 #) will enter the station’s user programming. (Default passwords shown for
this example).
System fixed numbering plan
The IVX fixed numbering plan assigns “fixed” numbers to all activities. This approach does not
allow for re-assignment of numbers (flexible numbering plan) but provides installation, wiring, and
user interface simplicity.
Number Function
0 Operator
1–6 CO lines
100–111 Digital extensions
112 & 113 Analog extensions
199 Overhead paging port
290–299 Department pilots
300-309 Guest mailboxes
500 Broadcast mailbox
560–589 Feature codes
590–593 MOH recordings
600–699 System speed dial