Fault Code Fault Description Causes / Repair
020 Glow plug 1, interruption Measure cold resistance of the glow plug at approx. 20°C
ambient temperature – connector B1, PIN 7 and 10.
021 Glow plug 1, overload / short circuit If the values are as follows the glow plug is ok, if the values
downstream of (–) differ – replace the glow plug.
022 Glow plug 1, short circuit downstream Measured value:
of (+) • 12 volt – glow plug = 0.42 – 0.6 ohm
• 24 volt – glow plug = 1.2 – 1.9 ohm
If the glow plug is ok, check the lead harness of the glow plug
for continuity, short circuit and damage.
023 Glow plug 2, interruption Measure cold resistance of the glow plug at approx. 20°C
ambient temperature – connector B1, PIN 11 and 14.
024 Glow plug 2, overload / short circuit If the values are as follows the glow plug is ok, if the values
downstream of ground differ – replace the glow plug.
Measured value:
12 volt – glow plug = 0.42 – 0.6 ohm
24 volt – glow plug = 1.2 – 1.9 ohm
If the glow plug is ok, check the lead harness of the glow plug
for continuity, short circuit and damage.
025 Diagnostic line fault Check diagnostics cable for continuity, short circuit and
Heater remains ready for operation damage – connector B2, PIN B4.
if ok, check control box.
026 Glow plug 2, short circuit downstream see fault code 023 / 024
of (+)
029 Glow plug 2, Ignition energy too low Glow plug 2 energy input is too low (< 2000 W)
Check glow plug for continuity, short circuit and damage.
—> Fault code 023.
Check control box.
033 Burner motor, interruption Check the burner motor's connection leads for continuity, short
circuit and damage – connector B1, PIN 3, 6 and 9.
033 Burner motor, overload • Check burner motor for easy movement by manually rotating the
impeller.
if not smooth running, remove the blockage.
033 Burner motor, speed error / blocked if ok, replace control box / blower unit.
034 Burner motor short circuit
downstream of (+) or (–)
037 Water pump not working Check water pump.
Apply voltage to the water pump – connector B1, PIN 12 and 13
(power input = max. 4 A or 2 A)
If water pump does not rotate, replace water pump.
If water pump is ok –> replace control box / blower unit.
041 Water pump, interruption Check the water pump's connection and lead harness for con-
tinuity, short circuit and damage – connector B1, PIN 12 and 13.
If ok, check water pump —> fault code 037.
042 Water pump
Overload short circuit Water pump running dry.
043 Water pump Vent heater (water shortage), open heater slide valve, check
Overload downstream of +Ub water flow rate