Operating instructions

28
Maintenance, Troubleshooting & Repairs
Fault Code Fault Description Causes / Repair
047 Metering pump • Check the metering pump's connection and lead harness for
Overload short circuit continuity, short circuit and damage – connector B2, PIN A1.
If ok, check the resistance of metering pump – setpoint value
approx. 20 ohm.
048 Metering pump interruption
049 Metering pump
Overload downstream of +Ub
050 Too many attempted starts Control box locked due to repeated switching on in succession
Control box is locked without flame detection (fault code 052).
• Check fuel supply, exhaust and combustion air system.
• Check glow plug –> see fault code 019 to 024 / 026 / 029.
• Check flame sensor –> fault code 064 / 065.
• Unlock the control box by deleting the fault memory.
052 Exceeding of safety time No flame detected within the start phase. Flame sensor value <
80°C,
therefore automatic shutdown because safety time exceeded.
• Check fuel supply, exhaust and combustion air system.
• Check glow plug –> see fault code 019 to 024 / 026 / 029.
• Check flame sensor –> fault code 064 / 065.
053 Flame cutout in Heater ignited (flame detected) and signals flame cutout during a
"POWER" control stage power stage.
• Check fuel quantity, blower speed, fuel supply, exhaust and com-
bustion air system.
054 Flame cutout in "HIGH" control stage • Check flame sensor –> fault code 064 / 065.
055 Flame cutout in "Medium" control stage
(D 8 W / D 10 W) "Medium1" control stage
(D 12 W)
056 Flame cutout in
"Medium 2" control stage (D 12 W)
057 Flame cutout in
"Medium 3" control stage (D 12 W)
058 Flame cutout in "LOW" control stage
059 Too rapid rise in water temperature • Vent air from system, open heater slide valve, check water flow
rate.
• Check temperature sensor –> fault code 060 / 061
060 Temperature sensor interruption Temperature sensor signals temperature value outside the
measuring range.
061 Temperature sensor short circuit • Measure the resistive value of the temperature sensor,
Connector B1, PIN 1 and 2; for measured values. See page 44.
– If temperature sensor ok, check connection leads for continuity,
short circuit and damage.
064 Flame sensor interruption Flame sensor signals temperature value outside the measuring
range.
065 Flame sensor short circuit • Measure the resistive value of the flame sensor – connector B1,
PIN 5 and 8; for measured values. See page 45.
If flame sensor ok, check connection leads for continuity, short
circuit and damage.