User Manual

computer radio control system
PPM neg.- standard form of PPM signal generation with
negative logic at PPM outputs. The bus idle state is log.1.
PPM input - for the given input there a PPM signal is expected
from the connected receiver
JETIBOX EX - telemetry sensor connection or data stream for
JETIBOX
EX Bus/EX Bus HS - digital communication, when transmits
throw and telemetry information with configuration
possibilities of equipment connected to this bus, for instance by
a DC/DS transmitter. This configuration type is used, for
instance, when receivers are connected for example to Central
Box.
Serial UDI12/16 - serial data output suitable for connection of
devices with unidirectional UDI interface (e.g. Vbar).
PPM error code- in case of PPM input mode, an acoustic signal can
be set up to announce that this connected signal is missing. By
loading a character from the Morse alphabet you may set up tones
that will acoustically announce the absence of a PPM signal at the
given receiver output. This acoustical signal is generated by the
transmitter module. In the factory default setup the acoustical
signal is switched off.
SetInChannel - assignment of an actual output (labelled as Yx) or
input channel (labelled as Chx)
EN
16
JETI model s.r.o.
Lomená 1530, 742 58 Příbor
Czech Republic - EU
www.jetimodel.com
www.jetimodel.de
info@jetimodel.cz
Duplex-System EX:
• Transmitter modules
• Receivers
• Telemetric sensors
• Compatible accessories
• Display units
Duplex-System EX:
• Sendermodule
• Empfänger
• Telemetrische Sensoren
• Kompatibles Zubehör
• Abbildungseinheiten