User Manual

Specifications
EverGuard Control Panel
69
Communication
Modules:
Cellular network: GSM/GPRS Module
Quad band (850/900/1800/1900 MHz)
Transmission time:
The time measured from transmission by a wireless
detector to the time the system is requesting connection
from the cellular network.
SMS: 0.2 ±0.05 Sec
GPRS: 1 ±0.3 Sec
GSM data: 5.5 ± 1 Sec
Note that SMS message usually have much larger delays
over the cellular network than the other 2 link types.
GSM data delay could be reduced (preconfigured) on
certain cellular networks.
Functional
Bi-directional :
Instant system status feedback
Instant command Acknowledgement
Security Functionality:
5 Scenarios
32 Users
Silent SOS
Silent Duress Alarm
Internal Siren, up to 100dbA @1m (configurable)
Tamper detector (Top, Wall)
Extended Event Log with Time/Date stamp
Home Automation:
Wireless control of electrical appliances
Remote Interactivity:
Remote software upgrades
Remote programming and configuration
Long range digital
voice verification:
High quality
Two-way digital audio
Enhanced echo cancelling DSP-based algorithm
Speaker programmable gain
Safety functionality:
Separate safety alarm, up to 100dBA @1m (configurable)
Various detectors (water, gas, smoke etc.)
Various panic (SOS) devices
Environmental
Operating
Temperatures:
0°~50° Celsius (32° - 122° Fahrenheit)