KEY FEATURES
 • 3SequencerTimingSectionsFixed3-SecondIntervals,6SecondsTotal
 • 9TotalOutletsAreProvided
 • 6RearPanelOutletsAreSequencedInThreeSteps
 • 2FrontPaneland1RearPanelUnswitchedConvenienceOutlets
 • RFINoiseFilteringtoReduceRadioFrequencyInterference
 • EMIToReduceElectromagneticInterference
 • DualClampingSpike&SurgeSuppression,DCSCircuitry
 • FrontPanelDigitalACMainsVoltmeter
 • LEDIndicationofReversed“Live”and“Neutral”Wiring
 • AbnormalACLineVoltageIndicatorforVoltagesBetween101V–107Vor128V–132V
 • ExtremeVoltageShutdown(EVS)Below101VorAbove132VACLine
 • CircuitBreakerProtection@15AIndicatedby“BreakerOpen”Indicator
 • FrontMountedPull-outLEDLightWith2-PositionDimmer
 • RearMountedXLRConnectorfor12VDCLEDLamp(Lampsoldseperately,AtlasPowermodelAP-GNL18)
 • ExternalSwitchSequenceTriggerActivation
 • ExternalDCVSequenceTriggerActivation5-24VDC
 • 24VDCSequenceTriggerOutputforOptionalExternalACOutlet
APPLICATIONS
TheETA-ECS3wasdesignedtobeflexiblewithfeaturesthatallowittobeusedinavarietyofapplications.Thesequencedoutputs
allow the turning of equipment on and off in a particular order, to eliminate an in rush of current and audible pops that often occur with 
non-sequenced power strips. It also can be used solely for protection against voltage surges. If fuzzy video or frequent static pops 
occur, the AC power conditioning will eliminate or reduce those inconveniences. The following are just a few examples of applications 
theETA-ECS3canbeused:
 • Restaurants
 • HousesofWorship
 • Schools
 • HomeTheaters
 • OfficeBuildings
 • SportsBars
ETA-ECS3 