FRONT PANEL FEATURES 
1.   Unswitched AC Outlet – Thetwo120VACoutletsarealwayslivewhentheETA-ECS3powercordispluggedintoanACmains
powersourceandvoltageispresent.Ifvoltageispresentattheoutlets,itwillbedisplayedontheACMainsMeter.Note:TheAC
mains power switch or sequencer section does not affect the Unswitched AC Outlets. The Unswitched Outlets are protected by 
thesurgeprotectioncircuitry,butwillnotbeshutoffbytheEVScircuit.
2.   AC Mains Breaker – The15AratedbreakerwillopenifthecombineddrawofallACoutletsexceeds15A.Note:Thebreakersare
designed to exceed their rating for a short period of time. If the breaker is tripped, to reset you must first remove the load from 
theETA-ECS3andpushthecenterbuttononthebreaker.
3.  System Activation Switch – ToturntheETA-ECS3OnorOff,pressthemomentaryswitchonce.
4.  Pull Out Light – TheLEDlightisdesignedtobepulledoutwhenneeded.
5.   Pull Out Light Dimmer Switch – ThePullOutLightcanbeturned“On”or“Off”bythisswitch.Therearealsotwobrightness
settings. 
ETA-ECS3 
Power Sequencer & Conditioner
1 2 3 4 5