ETA-ECM2063 AC Power Distribution Sequencer ETA-ECM2063 AC Power Distribution Sequencer Raceway System 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800-321-6699 • Fax: 800-996-3821 – 1 – Specifications are subject to change without notice. ETAsys.
ETA-ECM2063 AC Power Distribution Sequencer TABLE OF CONTENTS Important Safety Instructions .................................................................................................................. 3 Introduction ............................................................................................................................................ 5 Key Features...............................................................................................................................
ETA-ECM2063 AC Power Distribution Sequencer IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
ETA-ECM2063 AC Power Distribution Sequencer • • • • • • • • • • WARNING – WHEN THE DEVICE IS IN USE To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to ETA Systems. Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the AC outlet and contact ETA Systems.
ETA-ECM2063 AC Power Distribution Sequencer INTRODUCTION Thank you for purchasing the ETA Systems ETA-ECM2063 AC Power Distribution Sequencer Raceway System. The ETA-ECM2063 is designed to offer the installer/contractor current requirement flexibility based on the needs of the equipment that will be connected to the raceway. The ETA-ECM2063 accepts up to three separate 20A 120VAC lines, allowing for up to a total of 60A to be divided throughout the system.
ETA-ECM2063 AC Power Distribution Sequencer RACEWAY AC INLET KNOCKOUTS The ETA-ECM2063 can support up to three AC conduit inlets at each end. There are three knockouts on both the top and the bottom of the raceway. Each inlet supports a double knockout size supporting standard USA electrical fittings of 1⁄2" and 3⁄4". The figure below is an illustration of one end of the raceway.
ETA-ECM2063 AC Power Distribution Sequencer CONFIGURING THE ETA-ECM2063 The ETA-ECM2063 is designed to be activated/triggered by a sequence controller like the ETA Systems ETA-SEQ6 or the ETA-ECS6RM. The ETA-ECM2063 can be configured to accept from 1 to 3 separate hard wired 20A circuits. There are three individual load sections in the ETA-ECM2063. Each load section has two separate sequence channels, with each channel having two 20A, 120VAC outlets.
ETA-ECM2063 AC Power Distribution Sequencer WIRING THE AC MAINS Below are four configurations for load distribution. After following the wiring diagram place the label of the Internal Wiring Configuration on the panel box. Note: All electrical wiring must be done by a certified electrician. Follow the steps below for wiring the AC mains. Accessing the Internal Wiring 1. Locate the Control Input Panel. 2. Remove the four screws. (See diagram below) 3. Remove the Control Input Panel.
ETA-ECM2063 AC Power Distribution Sequencer ETA-ECM2063 Load Wiring Option #1 - L1, L2, L3 = 20A In this load/current wiring configuration all 3 load sections (Channels 1 – 6) are connected to a single 20A AC Mains feed. Note: All electrical wiring must be done by a certified electrician. 1. Follow the steps listed in section “Accessing the Internal Wiring” 2.
ETA-ECM2063 AC Power Distribution Sequencer ETA-ECM2063 Load Wiring Option #2 - L1 & L2 = 20A, L3 = 20A In this load/current wiring configuration the load sections L1 & L2 (Channels 1,2,3, & 4) are connected to a single 20A AC Mains feed and load section L3 (Channels 5 & 6) is connected to second 20A AC Mains feed. Note: All electrical wiring must be done by a certified electrician. 1. Follow the steps listed in section “Accessing the Internal Wiring” 2.
ETA-ECM2063 AC Power Distribution Sequencer ETA-ECM2063 Load Wiring Option #3 - L1 = 20A, L2 & L3 = 20A In this load/current wiring configuration the load section L1 (Channels 1 & 2) is connected to a single 20A AC Mains feed and load sections L2 & L3 (Channels 3, 4, 5, 6) are connected to second 20A AC Mains feed. Note: All electrical wiring must be done by a certified electrician. 1. Follow the steps listed in section “Accessing the Internal Wiring” 2.
ETA-ECM2063 AC Power Distribution Sequencer ETA-ECM2063 Load Wiring Option #4 - L1 = 20A, L2 = 20A, L3 = 20A In this load/current wiring configuration the load section L1 (Channels 1 & 2) is connected to a single 20A AC Mains feed, load section L2 (Channels 3 & 4) is connected to second 20A AC Mains feed and load section L3 (Channels 5 & 6) is connected to third 20A AC Main feed. Note: All electrical wiring must be done by a certified electrician. 1.
ETA-ECM2063 AC Power Distribution Sequencer SPECIFICATIONS Type Electrical AC Power Distribution RoHS Compliant Yes Safety Listing ETL (UL60065 Standard) Front Panel Number of Channels 6 AC Outlets 12 NEMA 5-20, Switched Connectors Qty 6, 2 Position Phoenix Euro Block Style 3.
ETA-ECM2063 AC Power Distribution Sequencer NOTES: 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800-321-6699 • Fax: 800-996-3821 – 14 – ETAsys.com Specifications are subject to change without notice.
ETA-ECM2063 AC Power Distribution Sequencer NOTES: 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800-321-6699 • Fax: 800-996-3821 – 15 – ETAsys.com Specifications are subject to change without notice.
ETA-ECM2063 AC Power Distribution Sequencer LIMITED WARRANTY All products manufactured by ETA Systems are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any. This warranty shall extend from the date of purchase for a period of one year. Additionally, fuses and lamps carry no warranty.