Technical data

Flow meter FC01-Ex Flow meter FC01-Ex
Errors 59 Errors 59
Priority group III
Error Cause Rectification
No. 20 Medium temperature too low
No. 30 Over limits of flow rate
No. 31 Measuring range of flow velocity
below limits
(V < (1st trim point - 10%))
No. 60 Assignment of quantity per pulse too low*
No. 40 Controller error (oscillator-watchdog)
Admissible EMC levels may have been
exceeded
No. 41 Controller error (watchdog-timer)
Admissible EMC levels may have been
exceeded
* Error No. 60 can only occur with version FC01-Ex-U1T4.
Priority group III
Error Cause Rectification
No. 20 Medium temperature too low
No. 30 Over limits of flow rate
No. 31 Measuring range of flow velocity
below limits
(V < (1st trim point - 10%))
No. 60 Assignment of quantity per pulse too low*
No. 40 Controller error (oscillator-watchdog)
Admissible EMC levels may have been
exceeded
No. 41 Controller error (watchdog-timer)
Admissible EMC levels may have been
exceeded
* Error No. 60 can only occur with version FC01-Ex-U1T4.