Technical data
Flow Meter FC01-Ex Flow Meter FC01-Ex
64 Technical data 64 Technical data
8.5.2 Open collector outputs (DC switching voltage)
Pin selection: Signal name Pin XAH Polarity
/ ERROR emitter 1 -
/ ERROR collector 2 +
/ BUSY / PULSE emitter 3 -
/ BUSY / PULSE collector 4 +
Limit Switch 2 emitter 5 -
Limit Switch 2 collector 6 +
Limit Switch 1 emitter 7 -
Limit Switch 1 collector 8 +
Voltage level
Low level - active: U
ce
< 0,8 V for I
C
< 10 mA
U
ce
< 1 V for I
C
< 100 mA
High level - passive: U
ce
< 48 V 
U
ce max
= 60 V 
max. leakage current ≤ 25 µA
Reverse polarity protection: yes - I
max
< 1 A
Short-circuit protection: yes - I
max
< 1 A
Resistive load
Max. admissible switching capacity: 1.5 W
Max. admissible switching current: 150 mA
Max. admissible switching voltage: 36 V
Inductive load - L < 100 mH
(DC voltage - without external safety capacity)
Max. admissible switching capacity: 1.5 VA
Max. admissible switching current: 40 mA
Max. admissible switching voltage: 36 V
Capacitive Last - C < 20 µF
Max. admissible switching capacity: 1.5 VA
Max. admissible switching current: 1.5 A
Max. admissible switching voltage: 36 V
Insulation voltage: signal input - central electronic unit 500 V
signal input - signal input 500 V
8.5.2 Open collector outputs (DC switching voltage)
Pin selection: Signal name Pin XAH Polarity
/ ERROR emitter 1 -
/ ERROR collector 2 +
/ BUSY / PULSE emitter 3 -
/ BUSY / PULSE collector 4 +
Limit Switch 2 emitter 5 -
Limit Switch 2 collector 6 +
Limit Switch 1 emitter 7 -
Limit Switch 1 collector 8 +
Voltage level
Low level - active: U
ce
< 0,8 V for I
C
< 10 mA
U
ce
< 1 V for I
C
< 100 mA
High level - passive: U
ce
< 48 V 
U
ce max
= 60 V 
max. leakage current ≤ 25 µA
Reverse polarity protection: yes - I
max
< 1 A
Short-circuit protection: yes - I
max
< 1 A
Resistive load
Max. admissible switching capacity: 1.5 W
Max. admissible switching current: 150 mA
Max. admissible switching voltage: 36 V
Inductive load - L < 100 mH
(DC voltage - without external safety capacity)
Max. admissible switching capacity: 1.5 VA
Max. admissible switching current: 40 mA
Max. admissible switching voltage: 36 V
Capacitive Last - C < 20 µF
Max. admissible switching capacity: 1.5 VA
Max. admissible switching current: 1.5 A
Max. admissible switching voltage: 36 V
Insulation voltage: signal input - central electronic unit 500 V
signal input - signal input 500 V