OWNER’S MANUAL © SYSTEMS A Creative Light & Sound Company 1532 Enterprise Parkway • Twinsburg, Ohio 44087 330-425-3388 • 800-321-6699 • Fax: 330-425-9700 http://www.etasys.com E-mail eta@etasys.
ETA’s line of Conditioned Power Distribution units are designed to reduce damage to sensitive electronic equipment from sudden voltage spikes, damaging power surges, and EMI/RFI noise, which is inherent in utility power lines. The PD11SP is a sequential four step/stage power up/down conditioned power distribution unit.
The PD11SS is a sequential four step/stage power up/down conditioned power distribution unit. It is designed to protect electronic equipment that requires a time-delayed start-up, particularly when high in-rush current can potentially damage audio, video, or computer equipment at power up.
Pull out lights ON/OFF HI/LOW switch Digital Voltmeter Readout Protection "On" Indicator Power switch On / Off Breaker protected and unswitched 15 amp outlet 20 amp Breaker 15 amp Breaker Pull out lights Front View PD11LVP Model Shown Back View PD11P, 11VP, 11LP, 11LVP Protected "Always On” 20 amp Outlets Back View PD11LVSP 3 pin terminal block for re sequential operation of un Stage 1 Stage 2 Stage 3 Stage 4 Protected "Always On” 20 amp Outlets Easy 4-step bulb replacement.
PD11P, PD11VP, PD11LP, PD11LVP Features: • Light Switch (PD11LP/LVP/LVSP) activates rack illumination; choice of HI or LOW intensity • Light Tubes (PD11LP/LVP/LVSP) illuminates up to 25 rack spaces • 4 dual 20 amp U-grounded switched outlets per unit • 1 dual 15 amp U-grounded "always on" and protected outlet • Digital Voltmeter Readout (PD11VP/LVP/LVSP) displays incoming line voltage • Resettable 20 amp thermal circuit breaker; 15 amp for front panel outlet • Lighted Outlet Power Switch activates protectio
Installation Requirements PD11P, PD11VP, PD11LP, PD11SP, PD11LVP, PD11LVSP Plug unit into power source and observe status of four "Protection" light emitting diodes. The (green) “1st Stage”, “2nd Stage”, and “GROUND OK” L.E.D.’s should normally be illuminated and the (red) “FAULT” L.E.D. should be off. When these indications are present, test the power “On/Off” switch which will illuminate to indicate that power is being supplied to the switched outlets on the rear of the unit. A.
Three-Wire Remote Control Interface A three-wire remote control interface is added to the main PC board for the PD11SS, PD11SP AND PD11LVSP units. This remote control interface is accessible through an external terminal block on the back of the unit (see Figure 6). This interface requires an external user provided switch, L.E.D., and a three-wire cable to implement. The interface has been tested reliably over 1000 feet with 22-gauge speaker wire (see Figures 1 and 5).
ETA Conditioned Power Distribution... The Benchmark By Which Professionals Compare. For over 20 years ETA has developed, manufactured and sold high amperage theatrical lighting systems from which evolved an extensive line of rack mounted conditioned power distribution products designed to protect today’s sensitive electronic digital equipment.