Installation manual
Controls
6
• LED indicator for operating status
• Backlit
• Unit operation – On/Off
• Temperature control (°F or °C)
• Instantaneous room temperature display
• Cooling range 64–86 °F
• Heating range 60–86 °F
• Mode selection – Fan/Heat/Cool/Auto/Dry
1
• Fan speed – Low/Medium/High/Power/Auto
• External static pressure control
• Discharge vanes – Auto Swing/Fixed
2
1 : Mode will be determined by master indoor unit. Master indoor unit is designated by first unit on or by field setting.
2: Model specific; not available on all models. Availability depends on the indoor unit mode being controlled.
3: Requires optional Wired Remote Group Cable Assembly (PZCWRCG3; one per additional indoor unit and/or controller,
maximum of 4), except for 24-48 MBh 4-Way Ceiling Cassettes (TM, TN, TP frames).
4: Communication cable can be extended to a maximum 164 feet by using the Wired Remote Group Control Assembly
(PZCWRCG3) or Wired Remote Extension Cable (PZCWRC1), maximum of 4.
Simple
Controller
[Wired Remote
Controller]
(PQRCVCL0Q(W),
PQRCHCA0Q(W))
The standard Simple Controller allows control of indoor unit operation
mode, fan speed, and temperature setpoint. The controller is also available
without mode button for systems under central control, replacing it with
instantaneous room temperature display.
• Child lock
• Group control of up to 16 indoor units
3
• Multiple controllers per indoor unit or indoor unit
group
2,3
• Temperature sensor location – Unit/Controller/
Remote Sensor
• Error code display during unit or system malfunction
• 33 feet of communication cable included
4
• Device power provided by indoor unit
• Wireless remote controller receiver
Zone Controllers
PQRCVCL0QW
(White)
PQRCVCL0Q
(Black)
Simple Controller With Mode Selection Simple Controller Without Mode Selection
PQRCHCA0QW
(White)
PQRCHCA0Q
(Black)