Manual

English
4 Source Four HID PAR CE
Wiring and power information
A plug of at least 2.5 amp (220/240V) rating should be attached to the fixture’s mains lead. The wires in the mains
lead are 1.5mm
2
each and coloured in accordance with the following code:
WARNING: The CE Source Four HID PAR CE must be earthed.
Accessories
HID Lamp type and general information:
Do not use lamps other than the following types in the Source Four HID PAR CE. Use of lamps other than speci-
fied below will void CE safety compliance and your warranty.
Green and Yellow:
Earth
Blue: Neutral
Brown: Live
Current rating: 240V/2.5 amp maximum
Operating fre-
quency:
50/60Hz
ETC Part #
Colour frame (19 cm sq./17 cm.inside diameter) 7061A3047
Safety cable (79 cm) 7061A1022
C-clamp 7060A2009
Top hat, 7.62 cm PSF1022
Top hat, 15.24 cm PSF1023
Half hat PSF1027
Cross-baffle top hat PSF1031
Egg-crate louver PSF1028
Weighted base PSF1032
Gel Extender 7.62 cm PSF1030
Gel Extender 15.24 cm PSF1029
Barn door PSF1019
Lamp Type Manufacturing Codes Watts Base Bulb LCL Ave.
Hrs.
Initial
lumens
Color
temp
Ceramic
Metal
Halide
CDM-T 150W/830 150 G12 T6 56mm 9000 14000 3000°K
CDM-T 150W/942 150 G12 T6 56mm 9000 12700 4000°K
MD150T6/U/G12/
830
150 G12 T6 56mm 9000 14000 3000°K
MBI150/T/30 150 G12 T7 57mm 6000 11500 3000°K
MBI150/T/40 150 G12 T7 57mm 6000 11250 4000°K
t 180°c