Zoom CE User Manual Production Dates: September 2004 - Present C o p y r i g h t © 2 0 0 7 E le c tr o n i c T h e a t r e C o n t r o l s , I n c . All Rights reserved. P r o d u c t in f o r m a t i on a n d s p e c i f i c a t i o n s s u bj e c t t o c h a n g e . P a r t N u m b e r : 7060M1260-06.
Table of Contents Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Source Four Zoom CE guidelines . . . . . . . . . . . . . . . . . . . . . . . .2 Basic assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Luminaire information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Colour frame holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Replacing the HPL lamp . . . . . . . . . . . . . . .
English Declaration of conformity We, Electronic Theatre Controls, Europe Ltd.
English Source Four Zoom CE guidelines The Source Four Zoom CE is intended for professional use only. Read the entire User Guide before using equipment. WARNING: • • • • • • • • • • • • • • Please note the following safety precautions. Do not mount the Source Four Zoom CE on or near a flammable surface. Use the Source Four Zoom CE in dry locations only, where humidity does not exceed 90 percent. The luminaire is for indoor use only and is not intended for outdoor use.
English Basic assembly Insulated handle Lamp housing Yoke Retainer bolt Barrel Pattern holder slot Drop-in iris slot Color frame retaining gel clip Reflector housing Yoke locking knob Optional Balancing yoke 15°-30° lens tube Barrel rotation knob Shutters Focus dial 25°-50° lens tube Color frame WARNING: Figure 1 Please note the following safety warnings before use: Do not mount the luminaire on or near combustible surfaces. Do not operate the luminaire without a lens installed.
English HPL lamp table CAUTION: Do not use lamps other than the HPL in Source Four fixtures. Use of lamps other than HPL will void your warranty. Lamp code Watts Volts Initial Lumen Colour temp.
English Replacing the HPL lamp A lamp must be installed before you use the luminaire. HPL lamp Lamp retaining clips Lamp retention brackets Lamp housing Knurled bolt Figure 3 Note: Verify that the HPL lamp you intend to install is suitable for your facility’s voltage; 115-, 120-, 230-, and 240-volt HPL lamps are available. See HPL lamp table, page 4. Operating HPL lamps above their rated voltage reduces lamp life and can cause premature lamp failure. WARNING: Let the lamp cool before replacing.
English Centering lamp and adjusting the field Flat field-best adjustment Rear lamp housing Inner Knob peak/flat field adjustment Hot spot - lamp pulled out too far Field with hole - lamp pushed in too far Outer Knob - lamp center adjustment Figure 5 Figure 4 The two concentric knobs located on the lamp housing allow you to align the lamp and adjust its field. See Figure 4. The outer knob centers the lamp within the reflector. The inner knob adjusts the lamp’s field.
English Shaping the beam The beam can be shaped using the shutters (see Figure 8), a pattern, an optional drop-in iris, or by rotating the barrel. Pattern Projection The pattern holder slot is on the top side of the barrel and in front of the shutters. It accommodates A-size, B-size and glass pattern holders (see Figure 7). A-Size Pattern holder: holds 7.62 cm diameter patterns B-Size Pattern holder: holds 6.35 cm and 6.98 cm diameter patterns 7.92 cm dia. 9.4 cm Note: 6.98 cm 9.
English Rotating the barrel assembly Barrel rotation knob Figure 9 Step 1: Loosen the barrel rotation knob directly behind the shutters on the underside of the reflector housing (see Figure 9). Do not remove the barrel rotation knob. Step 2: Rotate the barrel to the desired position (up to 25° in either direction from the centered position). Step 3: Once the barrel is positioned, tighten the barrel’s rotation knob to lock it in place.
English Setting the angle within the yoke Figure 11 Yoke locking knob Step 1: Loosen the yoke locking knobs (see Figure 11). Do not remove them. Step 2: Tilt the luminaire to the desired position. Step 3: Tighten the yoke locking knobs to secure in position. Adjusting the optional balance yoke position — 15°-30° Zoom The Source Four 15°-30° Zoom has an optional balance yoke bracket (ETC part # 7060A2028) for repositioning the fixture’s center of gravity.
English Setting the angle within the moveable yoke Horizontal mounting Vertical mounting Yoke locking knob Figure 13 Step 1: Loosen the moveable yoke’s locking knobs. Do not remove them. Step 2: Tilt the luminaire to the desired position as shown in Figure 13. Step 3: Tighten the yoke’s locking knobs to secure the luminaire in position. Cleaning lens and reflector WARNING: Do not use ammonia-based or other harsh commercial cleaners. Clean lens and reflector only as directed.
English Cleaning the Reflector WARNING: Unplug the luminaire before attempting to clean the reflector. To quickly clean the reflector, remove the lens tube and clean the dust from the reflector with a blast of oil-free air. You may also wipe the reflector with a clean lint-free cloth. If either method is not sufficient, follow these steps. Step 1: To protect the lamp housing during cleaning, remove the lamp housing by loosening the knurled bolt and pulling the housing straight out. See Figure 3.