CE User Manual Production Dates: September 2004 - Present C o p y r i g h t © 2 0 0 8 E le c tr o n i c T h e a t r e C o n t r o l s , I n c . All Rights reserved. P r o d u c t in f o r m a t i on a n d s p e c i f i c a t i o n s s u bj e c t t o c h a n g e . P a r t N u m b e r : 7060M1210-06.
Table of Contents Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Source Four CE guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Basic luminaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Luminaire information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Colour frame holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Replacing the HPL lamp . .
English Declaration of conformity We, Electronic Theatre Controls, Europe Ltd.
English Source Four CE guidelines The Source Four CE is intended for professional use only. Read the entire User Guide before using equipment. WARNING: Please note the following safety precautions. • Do not mount the Source Four CE on or near a flammable surface. • Use the Source Four CE in dry locations only, where humidity does not exceed 90 percent. • The luminaire is for indoor use only and is not intended for outdoor use.
English Basic luminaire Earth continuity cable Secondary suspension point Primary suspension yoke mounting holes Lamp socket assembly Retainer bolt Drop-in iris slot Colour frame Retainer bolt Lens tube Reflector housing Yoke locking knob Reflector Gel retainer clip Barrel assembly Barrel rotation knob Shutters Gobo holder slot Beam focus knob Colour frame holder WARNING: Safety screen (19°, 26°, 36° and 50° only) Figure 1 Please note the following safety warnings before use: Do not mount the
English Luminaire information Wiring an d power information A plug of at least 2.5 amp (220/240V) rating should be attached to the luminaire’s mains lead. The wires in the mains lead are 1.55mm2 each and coloured in accordance with the following code: Green and Yellow: Earth Blue: Neutral Brown: Live WARNING: t 18 0°c This luminaire must be earthed. Current rating: 120V/5 amp maximum 240V/2.
English Colour frame holder Retaining clip in the locked position Figure 2 The colour frame holder is equipped with a spring-loaded retaining clip that prevents colour frames and accessories from falling out. See Figure 2. WARNING: Make sure all colour frame accessories are locked in position with the retaining clip before hanging the Source Four luminaire. Step 1: Release the retaining clip by pushing it sideways while gently pulling backwards. Step 2: Insert the colour frame.
English Replacing the HPL lamp Lamp retention brackets Lamp housing HPL lamp Lamp retaining clips Knurled bolt Figure 3 A lamp must be installed before you use the luminaire. Note: Verify that the HPL lamp you intend to install is suitable for your facility’s voltage; 115-, 120-, 230-, and 240-volt HPL lamps are available. See HPL lamp table, page 4. Operating HPL lamps above their rated voltage reduces lamp life and can cause premature lamp failure. WARNING: Let the lamp cool before replacing.
English Centering lamp and adjusting the field Flat field-best adjustment Rear lamp housing Inner Knob peak/flat field adjustment Hot spot - lamp pulled out too far Field with hole - lamp pushed in too far Outer Knob - lamp center adjustment Figure 5 Figure 4 The two concentric knobs located on the lamp housing allow you to align the lamp and adjust its field. See Figure 4. The outer knob centers the lamp within the reflector. The inner knob adjusts the lamp’s field.
English Shaping the beam The beam can be shaped using the shutters (see Figure 8), a gobo, an optional drop-in iris, or by rotating the barrel. Gobo Pro jection The gobo holder slot is on the top side of the barrel and in front of the shutters. It accommodates A-size, B-size and glass gobo holders (see Figure 7). A-Size Gobo holder: holds 7.62 cm diameter gobos B-Size Gobo holder: holds 6.35 cm and 6.98 cm diameter gobos 7.92 cm Diameter 6.98 cm Diameter 9.4 cm Figure 7 9.
English Step 3: Insert the iris or motorized gobo device. For an iris, install the flat side toward the shutters and make sure the iris handle extends from the slot. Step 4: Slide the slot cover back toward the shutters until it meets the iris handle. Leave enough space to move the iris handle. Step 5: Secure the drop-in iris slot cover by tightening the screws.
English Setting t he angle wit hin the yoke Yoke locking knob Figure 11 Step 1: Loosen the yoke locking knobs (see Figure 11). Do not remove them. Step 2: Tilt the luminaire to the desired position. Step 3: Tighten the yoke locking knobs to secure in position. Cleaning lens and reflector WARNING: Do not use ammonia-based or other harsh commercial cleaners. Clean lenses and reflector only as directed.
English Step 1: Remove the beam focus knob at the bottom of the barrel (see Figure 1). Remove the lens tube from the barrel. Step 2: Use a Phillips screwdriver to remove the brackets that hold the lens in place. Remove the lens from the tube. Step 3: Dip the lens in a clean isopropyl alcohol/water mixture (9 parts water to 1 part isopropyl alcohol). Step 4: Use a soft moistened nylon bristle brush to wash the lens’ smooth side in a linear (noncircular) motion.
English Portable appliance test (PAT) guidelines The Portable Appliance Test is a set of tests that must be administered to electrical equipment in the UK and some locations in Europe to ensure safety.The tests are typically carried out using a small PAT device. The PAT device connects to a power source and then attaches to the product via an electrical outlet and test probes. The PAT provides a simple pass or fail result, allowing rapid testing of large inventories.
English 13
Corporate Headquarters 3031 Pleasant View Road, P.O.