Designer v1.11.0 Instruction Manual

Network - Controller protocols
Network - Controller protocols
With a Controller selected, choose the Protocols tab which is also available from the Patch window:
Depending on the Controller type selected, the Protocols tab allows you to configure the available eDMX and
other output protocols:
Network 2 (Protocol)
TPC, revised MSC 1, 2 & 4
Though the TPC and MSC 1, 2 & 4 (revised hardware) only have a single Ethernet port, this port may be con-
figured with two IPaddresses - one for management data and the other for output protocol data. The default set-
ting is for this dual IP mode to be disabled, so that the same IP settings are used for management and output
protocol data. Dual IPmode is particularly useful for working with KiNet power supplies, which must use
10.xx.xx.xx addresses.
MSC X
The MSC X has a dedicated Ethernet Protocol port. The default setting is to obtain IP settings via DHCP but
static IP settings can alternatively be set as required.
- 151 -