User guide
26
Installation recommendations.
Remember there are specific standards that have to be strictly followed regarding the safety rules of electrical
installations and automatic gates and doors.
As for the legal requirements and standards that must be adhered to, please take notice of the following
points to ensure maximum safety and reliability of your installation.
- Before installing check the surrounding environment. Carefully evaluate any hazards which could be
physical damage (transiting vehicles, parts of trees falling etc.), possible contact with persons’ bodies
(insects, leaves, etc.), flooding hazards, or any others exceptional events.
- Check the main voltage numbers is the same as the numbers that are given on the rating plate and in
this manual.
- Check and make sure if there is suitable electrical protection against short circuits/power spikes and
proper earthing on the main supply.
- Remember the unit having main voltage running through it (electrocution hazard, fire hazard).
- Take care with the control unit; the parts may be subject to damage if the control unit is abused.
- Make sure that you have all the necessary materials, and they are suitable for this kind of use.
Basic function setting and applying.
1. Itinerary setting Opening & closing force self-learning.
Press ‘SET’ button and hold on until the LED displays
figure ‘1’, then adjust the up limit by pressing ‘up’
button. Fine-tuning ‘up’ or ‘down’ button to determine
the final up limit position then press ‘set’ button the
display turn into ‘2’ automatically. Adjust the down limit
by pressing ‘down’ button. Fine-tuning ‘up’ or ‘down’
button to determine the final down limit position then
press ‘set’ button. The opener will operate a cycle
automatically to remember the limit positions and the
opening & closing force.