User Manual
14
Note:
• When nothing is being measured, the display
will show fixed value (intrinsic capacitance).
For small capacitance measurements, this fixed
value must be subtracted from the measured
value to ensure measurement accuracy. You can
also choose the relative measurement function
(REL) to automatically subtract the intrinsic
capacitance.
• The display will show “ ” if the measured
capacitor is short-circuited or the capacitance
exceeds the maximum range.
• When measuring large volume capacitors, it is
normal to wait for several seconds to obtain a
stable reading.
• When measuring capacitance of 100nF or above,
select relative measurement mode (REL) to
ensure accuracy.
Capacitance Measurement
WARNING
Before measuring, switch off the power
supply of the circuit, and fully discharge
all capacitors.
1. Turn the rotary dial to the capacitance
( ) position. Press SELECT three times
to choose the capacitance test. [Figure 6.1]
2. Insert the black test lead into the COM
terminal, and the red test lead into the
terminal.
3. Connect both test leads to both ends of the
capacitor. Hold the leads in place until the
reading on the display stabilizes.
SELECT
Figure 6.1
Hz
A
mA
µA
mV
V
V
OFF
NCV
Ω
°F°C