Installation guide

28
WATER FLOW AND WATER TEMPERATURE
The flow rate through the water heater is limited to a maximum of 26.0 (or 20.0) l/min.
The temperature setting, along with the supply temperature of the water will determine
the flow rate output of the unit.
Please refer to the temperature vs. litre per minute chart to determine the likely flow
rates based on your local ground water temperature and your desired outlet water
temperature combination.
WARRANTY CONDITIONS
Please contact your Eternity office for full warranty conditions on 1300 367
565 for all Warranty and Service information.
27G022-2
Out Put Temperature vs. l/min (Max. 26 l/min) with Various Ground Water Temperature
Correct Gas pipe size can be expect this chart
0.0
5.0
10.0
15.0
20.0
25.0
30.0
Out put Hot Water Temperature
Out Put Hot Water l/min
5
10
15
20
5
20.1 19.5 19.0 18.4 17.9 17.4 17.0 16.5 16.1 15.7 15.3 14.3 12.9 11.7 9.2
10
23.9 23.0 22.2 21.5 20.8 20.1 19.5 19.0 18.4 17.9 17.4 16.1 14.3 12.9 9.9
15
26.0 26.0 26.0 25.8 24.8 23.9 23.0 22.2 21.5 20.8 20.1 18.4 16.1 14.3 10.7
20
26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 25.8 24.8 23.9 21.5 18.4 16.1 11.7
37 38 39 40 41 42 43 44 45 46 47 50 55 60 75
Model26
Out Put Temperature vs . l/min (Max. 20 l/min) with Var ious Ground Wate r Te mpe rature
Correct Ga s pipe size c an be e xpect this chart
0.0
5.0
10.0
15.0
20.0
25.0
Out put Hot Water Temperatur e
Out Put Hot Water l/min
5
10
15
20
5
16.3 15.8 15.4 14.9 14.5 14.1 13.7 13.4 13.1 12.7 12.4 11.6 10.4 9.5 7.5
10
19.3 18.7 18.0 17.4 16.8 16.3 15.8 15.4 14.9 14.5 14.1 13.1 11.6 10.4 8.0
15
20.0 20.0 20.0 20.0 20.0 19.3 18.7 18.0 17.4 16.8 16.3 14.9 13.1 11.6 8.7
20
20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 19.3 17.4 14.9 13.1 9.5
37 38 39 40 41 42 43 44 45 46 47 50 55 60 75
Model20