Specifications
EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015C-22.A
C
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Installation Data
Start-Up Procedure
•  With the plug correctly wired 
but not mounted to the load 
provide with a DC power 
supply (See table).
• Apply the command signal 
  (ON) and check the Power 
  ON LED (RED) illuminates. 
  Reduce the signal to the 
  Command signal (OFF) level 
  and check the LED (RED) 
  goes out.
• If there is malfunction to the 
LED replace the plug.
• Switch off the power sup-
ply and command signal 
and connect the plug to the 
load. Ensure that the inter-
face seal is correctly fitted 
and clamped between the 
mounting faces (essential for 
IP65 protection). Tighten the 
retaining screw.
• Ensure that no damage 
or injury will occur on the 
machine when the valve is 
operated.
• Switch on the power supply. 
Apply the command signal.
  (a) Observe Power On LED 
    (RED) is ON.
  (b) Observe PWM LED 
    (Orange) is ON.
If LED is not operated then 
there is short circuit in the 
load. Replace the load/load 
coil.
• Successful completion of 
  these steps means that the 
  plug and load are ready for 
  normal use.
Spare Parts
The only spare part available is 
the interface seal, part number 
732100.
Ordering Procedure
Order plug by full model code, 
and spare interface seals by 
part number 732100.
.B