Specifications
EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015 C-23.A
C
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Electronic Controls
“Soft Switch” Power Plugs
0V
24V DC
Power 
input
Command
Signal
Power
amp.
PWM
Dither
Gain
Ramp
+
–
1
2
3
4
(NC)
Max.
limiter
X1
X2
2k7W
Solenoid
Deadband
Electrical Block Diagram
EHH-AMP-702-C-* 
10 Series
Note: This product has been 
designed and tested to meet 
specific standards outlined in 
the European Electro-magnetic 
Compatibility Directive (EMC) 
89/336/EEC, amended by 
91/26/EEC, 92/31/EEC and 
93/68/EEC, article 5. For 
instructions on installation 
requirements to achieve  
effective protection levels, see 
this leaflet and the Installation 
Wiring Practices for Vickers 
Electronic Products leaflet 
2468. Wiring practices relevant 
to this Directive are indicated 
by a warning symbol and 
Electromagnetic Compatibility 
(EMC).
EHH-AMP-702-C-* 
10 Series
For use with valve types:
EPV**-12D-1*
EFV1-**-012DE*
ERV1/2**-12D-1*
EPRV1/3**-12D-1*
ESV1**-12D-1*
IRV**-012D-1*
PFR21*
PFR24*
PDR21A*
PPD22**-012D-1*
Application
Focus applications for this plug 
are in the control of hydraulic 
solenoid operated directional 
and pressure control valves 
where control of valve response 
time can significantly reduce 
shocks in the hydraulic system.
Best results in reducing 
hydraulic shocks will only be 
obtained by using valves with 
the right “low shock”, or “ 
proportional” features. 
General Description
These plugs, conforming to 
ISO 4400/DIN 43650 interface, 
offer adjustable, ramped on/off 
switching times through the 
use of an integral amplifier.
The switching time range  
is 50 ms to 5 seconds.
The soft switch plug is rated 
for 24V DC nominal and  
controlled by a 24V logic  
signal. Applying an “on” signal 
causes the output current to 
ramp up to, and stay at, an 
adjustable maximum while the 
“on” signal is maintained. At 
“switch-off” the output current 
is ramped down to zero and 
will remain at zero until the 
next “on” signal.
Ramp times (switching times) 
can be adjusted by an in-built 
potentiometer.
An adjustment also allows  
for compensation of any  
deadband in the valve.
Features and Benefits
• Integral amplifier provides 
control from on/off logic 
command signal
• Adjustable ramp time
• Deadband compensation
• Adjustable output level
• Adjustable dither
• EMC to latest European 
standards
• Improved switching time 
repeatability
• Fully short-circuit and 
reverse-polarity protected
• Protection to IP67
.B