Specifications
EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015C-28.A
C
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Installation Data
Start-Up Procedure
• Correctly wire the plug and,  
before mounting it on the  
valve solenoid, apply 24V 
DC (18 to 36V limits) to the 
“power input” terminals.
• Check for correct plug  
function by illumination/  
non-illumination of the LED: 
  a. Apply less than 2 to 3  
volts to the input terminal: 
LED should not be  
illuminated.
  b. Increase voltage: the LED 
should illuminate when 
the voltage reaches 11V. 
Do not exceed 30V  
command signal.
  c. Decrease voltage: the LED 
should go off when the 
voltage is less than 5V.
• Switch off power supply and 
command/input signal and 
then install plug on solenoid. 
Ensure that all seals are  
fitted correctly and clamped 
as the retaining screw is 
tightened: this is essential in 
providing IP67 protection.
• Ensure that the hydraulic  
system will not cause any 
erratic movement of  
actuators, then:
  – Switch on power  
supply again.
  – Repeat LED/function  
check as in 2.
   An LED malfunction now 
indicates a short circuit at 
the load.
• Successful completion of 
these checks means that  
the plug and load are ready 
for use.
Spare Parts
The only spare part available is 
the interface seal, part number 
732100.
Ordering Procedure
Order plug by full model code, 
and spare interface seals by 
part number 732100.
.B