Product Instructions

EN Installation
04/2020 7 / 20
Installation
Installation Requirements
Read before installing
Trackers mounted on tools must be always visible by the tracking base.
Avoid metallic structure between trackers and tracking base.
All devices (tracking bases, trackers) must be inside 15/20 m (49/65 feet) radius from the Master tracking base.
When the communication is set to USB, the Master Tracking Base cannot be positioned more than 5 m (16 feet)
from CONNECT.
Place the tracking base next to the center of the working space.
Place the tracking base 2 meters (6.5 feet) maximum above the floor.
Other UWB systems may interfere with communication used between trackers and tracking base.
The UWB radio channel used for communication can be modified by using CVIMONITOR.
Minimum firmware and software releases
Product Release
CONNECT V 2.1.5.x
CVI CONFIG V 2.3.4.x
CVIMONITOR V 1.7.8.x
Defining the communications settings for the Master tracking base
Before installing the Master tracking base in the workstation, check its communication settings.
Plug the USB-C cable from the Master tracking base to the computer where CVIMONITOR is installed.
Launch CVIMONITOR. Minimum firmware and software releases [Page7]
Click the tab Tracking base.
When the tracking base is displayed, click Select.