Model 3625/2 Line Impedance Stabilization Network (LISN) User Manual
ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall constitute ETS-Lindgren Inc. assuming any liability whatsoever arising out of the application or use of any product or circuit described herein. ETS-Lindgren Inc. does not convey any license under its patent rights or the rights of others. © Copyright 1999–2013 by ETS-Lindgren Inc. All Rights Reserved.
Table of Contents Notes, Cautions, and Warnings ................................................ v 1.0 Introduction .......................................................................... 7 Data ............................................................................................................ 7 ETS-Lindgren Product Information Bulletin ................................................. 7 2.0 Maintenance .........................................................................
This page intentionally left blank. iv www.ets-lindgren.
Notes, Cautions, and Warnings Note: Denotes helpful information intended to provide tips for better use of the product. Caution: Denotes a hazard. Failure to follow instructions could result in minor personal injury and/or property damage. Included text gives proper procedures. Warning: Denotes a hazard. Failure to follow instructions could result in SEVERE personal injury and/or property damage. Included text gives proper procedures.
This page intentionally left blank. vi www.ets-lindgren.
1.0 Introduction The ETS-Lindgren Model 3625/2 Line Impedance Stabilization Network (LISN) is a two-channel low pass filter network built with a 5 µH coil. It is designed to isolate an electrically-operated device from an external power source so that high frequency conducted measurements may be made in accordance with certain electronic standards as specified by the FCC and MIL-STD.
This page intentionally left blank. 8 Introduction www.ets-lindgren.
2.0 Maintenance Only trained service personnel should perform adjustments and/or service procedures. Inside the Model 3625/2 are LETHAL voltages with which you could come into contact. Capacitors inside the unit may still be CHARGED even when the unit is disconnected from power. Before performing any maintenance, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment.
This page intentionally left blank. 10 Maintenance www.ets-lindgren.
3.0 Specifications Electrical Specifications Frequency Range: 100 kHz–65 MHz Lines plus Ground: 2 Maximum Load Capacity: 25 A This rating may be increased to 30 A provided that the duty cycle is reduced to 20%. Maximum Voltage Line-to-Ground: 220 VAC Maximum line-to-line voltage must not exceed 220 volts AC RMS. Line-to-Line: 400 VAC Maximum line-to-ground voltage must not exceed 440 volts AC RMS.
Physical Specifications 12 Height: 16.5 cm (6.50 in) Width: 27.9.cm (10.98 in) Depth: 27.9 cm (10.98 in) Weight: 5.4 kg (12.0 lb) Specifications www.ets-lindgren.
4.0 Installation and Application Before connecting any components, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment.
Ground Contact An RF ground stud is provided on the front panel and back panel for bonding to the ground plane. Ground contact can be made through the receptacle marked GND or through the brass stud on the back panel. If a ground contact to the Equipment Under Test (EUT) is made to the power supply ground, it may be made through the GND receptacle or the ground stud on the front panel. No ratio isolation is provided in this line.
Appendix A: Warranty See the Product Information Bulletin included with your shipment for the complete ETS-Lindgren warranty for your Model 3625/2. DURATION OF WARRANTIES FOR MODEL 3625/2 All product warranties, except the warranty of title, and all remedies for warranty failures are limited to two years. Product Warranted Duration of Warranty Period Model 3625/2 Line Impedance Stabilization Network (LISN) 2 Years www.ets-lindgren.