Installation, Operation and Maintenance ULTRA-QUIET H SERIES Wallmount Heat Pumps REV.
TABLE OF CONTENTS INSPECTION AND UNPACKING A thorough inspection of the shipping container should be made immediately upon receiving your unit. Look for any punctures or openings. If it appears as if damage has occurred, it should be noted on the freight bill before signing. The delivering carrier should be contacted immediately to inspect damage, and no installation work should begin until this inspection is completed. Introduction .........................................................................
OPERATING INSTRUCTIONS Set the thermostat to either HEAT or COOL as desired. Set the desired temperature on your thermostat dial and set the fan switch to “ON” (for continuous air circulation) or to “AUTOMATIC” (for air circulation only when the air conditioning system is operating). If you desire to vary the thermostat temperature setting during the day for energy conservation (for example, while you are at work) do not vary the setting more than 5°F from your normal temperature setting.
INSTALLATION D. DUCTWORK A. CODES The installer SHALL comply with all local, state, and federal codes and/or regulations pertaining to this type of equipment and its installation. Such codes and/or regulations should take precedence over any recommendations contained herein in lieu of local codes. Installations SHALL be made in accordance with the National Electrical Code, local codes, and recommendations made by the National Board of Fire Underwriters. 1.
! J. UNIT INSTALLATION WARNING: ELECTRICAL EQUIPMENT SHOULD BE INSTALLED BY A QUALIFIED, LICENSED ELECTRICIAN. IMPROPER ELECTRICAL HOOK-UP MAY DAMAGE EQUIPMENT, CAN CREATE A HAZARD, AND WILL VOID WARRANTY. H SERIES UNITS ARE FOR USE IN SINGLE-STORY BUILDINGS ONLY 1. As previously stated, the wall that the unit is to be installed onto MUST be strong enough to support the unit under the condition for which it will be used.
DEFROST TIME SELECTION M. DEFROST CONTROL The defrost control has three selectable time intervals: 30, 60 and 80 minutes. The timing is factory set at 60 minutes. This timing has been determined by testing to provide the best operating efficiency. In areas where the humidity is lower than normal, the timer may be set to a higher time (80 minutes). To change the time, move the timer jumper to the post marked 30 for 30 minutes, 60 for 60 minutes, or 80 for 80 minutes.
EXPLODED PARTS DRAWING — H24 / H30 / H36 7
EXPLODED PARTS DRAWING — H42 / H48 / H60 8
REPLACEABLE PARTS FOR H SERIES WALLMOUNT HEAT PUMP UNITS PART # DESCRIPTION H24B-1 H30B-1 H36B-1 H48B-1 1 COMP-MTGB COMP MTG GROMMET SCROLL H24-60 X X X X 2 162600020001 COMPRESSOR ZR22KC-PFV 230V 1PH X 2 162600030001 COMPRESSOR ZR28KC-PFV 230V 1PH 2 162600010001 COMPRESSOR ZR34KC-PFV 230V 1PH 2 053230 COMPRESSOR ZR40KC-PFV 230V 1PH 2 053253 COMPRESSOR ZR47KC-PFV 230V 1PH 2 053256 COMPRESSOR ZR57KC-PFV 230V 1PH 2 162600070001 COMPRESSOR ZR22K3-TF5 230V 3PH 2 162600070005
REPLACEABLE PARTS FOR H SERIES WALLMOUNT HEAT PUMP UNITS PART # DESCRIPTION 17 2023-5002H BASE PAN ASSEMBLY H42-60 18 550792 REVERSING VALVE V6 ASSEMBLED WITH COIL 21 451989 H24B-1 H30B-1 X H36B-1 X X H48B-1 H60B-1 X X X X HIGH PRESSURE SWITCH - AUTO RESET X X X X X 21a 0445-0007 DEFROST TERMINATION STAT X X X X X 22 2021-5018 BLOWER MNTG TRAY H24 X 22 2022-5018 BLOWER MNTG TRAY H30-36 X X 22 2023-5018-4 BLOWER MNTG TRAY H42-48 22 2023-5018-5 BLOWER MNTG TRAY
REPLACEABLE TABLE FOR H SERIES WALLMOUNT HEAT PUMP UNITS PART # DESCRIPTION H24B-1 H30B-1 H36B-1 H48B-1 36 0430-0074 **HEATER ELECTRIC 5 kW X X X X H60B-1 X 36 0430-0072 **HEATER ELECTRIC 10 kW X X X X X 36 0430-0090 HEATER ELECTRIC 7 kW X X X X X 36 458008 HEATER ELECTRIC 3 kW 230V 3 Phase 36 458009 HEATER ELECTRIC 6 kW 230V 3 Phase 36 458010 HEATER ELECTRIC 9 kW 230V 3 Phase 36 458011 HEATER ELECTRIC 11 kW 230V 3 Phase 36 458014 HEATER ELECTRIC 3 kW 460V 3 Phas
CONTROL BOX CONTROL BOX PARTS LIST ITEM 1 1 1 2 3 3 3 4 4 4 4 4 4 4 4 4 5 6 6 7 7 8 9 9 10 11 12 12 13 14 15 16 16 17 18 19 20 PART DESCRIPTION 453150 453770 453772 452842 450205 450325 450375 450360 450361 450362 450368 450364 450370 450371 0400-0033 0400-0031 451000 454252 040500 452200 452190 453151 2022-5031 654600-F 456175 451049 042004 451955-KIT 0415-0028 451840 452190 PTCR-3 PTCR-5 454393 452200 0451995 452195 COMPRESSOR CONTACTOR 1 POLE 1PH 25 AMP COMPRESSOR CONTACTOR 2 POLE 1PH 40 AMP COMPRES
UNIT DIMENSIONS MODEL A B C D 281/16 H24 36 34 18 5/8 H30/36 40 38 18 5/8 281/2 41 271/2 H48 H60 431/8 24 E F G H I J K L M N P Q R S 12 201/2 8 17/8 20 289/16 11/8 711/2 21/2 101/2 181/2 261/2 347/8 11/8 14 18 8 17/8 28 289/16 11/8 711/2 21/2 101/2 181/2 261/2 39 11/4 181/4 363/8 10 21/4 30 361/2 87 21/2 101/2 42 11/8 193/4 16 30 11/8 181/2 261/2 T 16 U V W X Y Z 32 115/16 2 9/16 291/2 271/8 275/8 391/2 2 9/16 291/2 27 1
FIELD WIRING SPECIFICATIONS FOR H MODEL UNITS [1] MODEL NO. AND ELECTRIC HEATER kW H24B00A1 05 10 H30B00A1 05 10 H36B00A1 05 10 15 H48B00A1 05 10 15 H60B00A1 05 10 15 H36B00A3 06 11 H48B00A3 06 11 18 H60B00A3 06 11 18 H60B00A4 06 11 15 VOLT/ PHASE 60 HERTZ 208-230/1 208-230/1 203-230/1 208-230/1 208-230/1 208-230/3 208-230/3 208-230/3 460/3 NO. OF FIELD POWER CKTS.
NOTES 18
NOTES
CE IFIED TO A R C I O IT UN TIO MPLYING DI A N R AIR Y CO U MAN FACTU RT S R A RE ARI performance certified, ETL certified NING A E I TI FI T IO F UIPMEN • R Q C S TA T I O N S E C T D ANDAR O C R NS 2 0 • E R 1 The information in this manual supersedes and replaces the previous instruction/operation manual with regards to H Series wallmount products. All product specifications reflect available information at the printing of this brochure.