Operating Instructions

Operating Instructions
Transponder-Coded Safety Switch CTP/CTA-L1/2-BP
22
(translation of the original operating instructions) 2537377-02-07/21
11.3.2. Acyclical data (device data and events)
Table 4: Acyclical data (examples)
Command
Answer
(number of bytes)
Category
Use in device
classes
Dec Bin Hex Meaning
General information
1 1 1
2 10 2
Send device ID-number/
serial number
6 PWR-UP All
3 11 3 Send device Versions
number
5 PWR-UP All
4 100 4
5 101 5 Complete number of
participants
2 PWR-UP All
6 110 6
7 111 7
8 1000 8
9 1001 9
10 1010 A Blinking frequency and
LED position
1 Control data Only EXTENDED
11 1011 B
12 1100 C
13 1101 D
14 1110 E
15 1111 F
16 10000 10
17 10001 11 Number of switching
cycles (Solenoid)
3 Additional All
18 10010 12 Send current error
code
1 Error All
19 10011 13 Send last error code 1 Error All
20 10100 14 Request of size of
error log
1 Error All
21 10101 15 Send error with
number
1 Error All
22 10110 16 Send detected tag
code
5 Transponder All
23 010111 17 Send taught tag code 5 Transponder All
24 011000 18 Send blocked tag
code 1
5 Transponder All
25 011001 19 Voltage (Power supply) 2 Additional All
26 011010 1A Temperature 1 Additional All
27 011011 1B Number of switching
cycles (Door position)
3 Additional All
28 011100 1C
29 011101 1D Reset device (Soft-
Reset)
1 Reset All
30 011110 1E Factory reset 1 Reset All
31 011111 1F
32 100000 20
. . .
. . .
. . .
63 111111 3F
For more information on these and other acyclical data, refer to the operating instructions for your BR-/IO-Link Gateway.