SDS
Fujian Nanping Nanfu Battery Co.,Ltd
3
•
The load resistance of the total circuit is accurate within ± 0.5% of the specified value
•
The Storage conditions of Delayed discharge test are 20±2
℃
, 55±20% RH
•
Normal value means the average of multiple test results from long-term monitoring which is
for reference only.
•
MAD means minimum average duration
•
The initial battery refers to batteries produced within 60 days
•
Marked with
※
is a quick test item for shipment release
Service output
Test condition Initial
After
12months
storage
After
60months
storage
Application Load Daily period
End
voltage
(
V)
Unit Normal MAD
Motor/Toy 3.9Ω 1h/d 0.8 h 8.4 7.6 7.0 6.4
Toy, non-motorized 250mA 1h/d 0.9 h 8.6 7.7 7.1 6.5
Digital still camera
1.5W-2s/
0.65W-28s
5m/h,24h/d 1.05 pulse 130 108 90 80
Photo flash 1000mA
10s/m
,
1h/d
0.9 pulse 530 451 396 342
CD, digital audio,
wireless gaming and
accessories
100mA 1h/d 0.9 h 25.0 22.5 20.7 18.9
Radio/Clock/
Remote Control
50mA 1h/8h,24h/d 1.0 h 52.0 46.8 43.1 39.3
Portable
Lighting(LED)
3.9Ω 4m/h,8h/d 0.9 min 450 405 373 340
※
100mA 24h/d 0.9 h 25.4 21.7 20.0 18.2
5. Leakage resistance of batteries
5.1 Over-discharge test
5.2 High temperature storage
Over-discharge test
Temperature
and humidity
Method Requirements
20±2℃
55±20%
After measured discharge capacity,
continue discharge until load voltage
drop to less than 40% of original
No leakage and no
deformation
High temperature storage
Temperature and humidity Time Requirements
60±2℃
90±5%
20Days No leakage