--- FUJI Confidential ---
图 1 温度循环流程示意图
Charge the battery per section 4.4 and place the battery at
25℃±2 ℃ temperature control chamber and go through
the following steps (see figure 1):
a) Place the battery at 75 ℃ ±2 ℃ test chamber and
maintain for 6 hours.
b) Decrease the test chamber temperature to -40℃±2℃
and maintain for 6 hours.
c) The temperature transition time is no greater than 30
minutes.
d) Repeat step a to step b, cycle 10 times in total.
5.3 安全保护性能
(注:以下安全性能试验应在有保护措施的条件下进行。)
Safety and Protection Performance Note: Adequate safeguard should be employed in conducting the
following tests.
序号
No.
检验项目
Test item
检验方法
Test method
判定标准
Criteria
5.3.1 过充电保护
Over charge
protection
电池按 4.4 规定充电结束后,将电池以 2 倍标称电压、2C
5
A
电流恒流恒压充电 7h,电池应符合判定标准。
Charge the battery per section 4.4, and then charge the
battery at constant voltage of 2 times of the nominal
voltage and at constant current of 2 C
5
A for 7 hours.
After the test. The battery should meet the criteria.
电池应不泄漏、不泄气、不
破裂、不起火和不爆炸。
No leak, no venting, no
rupture, no fire and no
explosion.
5.3.2 过放电保护
Over discharge
protection
电池在环境温度为 23℃±2℃条件下,以 0.2C
5
A 放电至终
止电压后,外接 30Ω负载放电 7h,电池应符合判定标准。
Discharge the battery at 0.2 C
5
A to the cut-off voltage at
ambient temperature of 23℃±2 ℃. And then discharge
the battery by connecting the battery to a load of 30Ω for
7 hours. After the test, the battery should meet the
criteria.
电池应不泄漏、不泄气、不
破裂、不起火和不爆炸。
No leak, no venting, no
rupture, no fire and no
explosion.
5.3.3
短路保护
Short-circuit
protection
电池按 4.4 规定充电结束后,将正负极用 80mΩ±20 mΩ
电阻器短路 1h 后,电池应符合判定标准;将正负极断开,
电池以 1C
5
A 电流瞬时充电 5s 后用电压表测量电池电压,
应符合判定标准。
Charge the battery per section 4.4, and then short-circuit
the battery for 1 hour by connecting the positive and
电池应不泄漏、不泄气、不
破裂、不起火和不爆炸。瞬
时充电后,电池电压应不小
于 3.6V。
No leak, no venting, no
rupture, no fire and no