SDS

文件名称
File Name
电池规格书
Battery Spec.
产品型号
Product model
18650(1INR19/66-4)
文件编号
Document No.
文件版本
Version
A2
日期
Date
2021-05-12
页码
Page
8/ 18
--- FUJI Confidential ---
1 温度循环流程示意图
Charge the battery per section 4.4 and place the battery at
25±2 temperature control chamber and go through
the following steps see figure 1:
a) Place the battery at 75 ±2 test chamber and
maintain for 6 hours.
b) Decrease the test chamber temperature to -40±2
and maintain for 6 hours.
c) The temperature transition time is no greater than 30
minutes.
d) Repeat step a to step b, cycle 10 times in total.
5.3 安全保护性能
(注:以下安全性能试验应在有保护措施
Safety and Protection Performance Note: Adequate safeguard should be employed in conducting the
following tests.
序号
No.
Test item
Test method
判定标准
Criteria
5.3.1
Over charge
protection
电池按 4.4 规定充电结束后,将电池以 2 倍标称电压2C
5
A
电流恒流恒压充电 7h,电池应符合判定标准。
Charge the battery per section 4.4, and then charge the
battery at constant voltage of 2 times of the nominal
voltage and at constant current of 2 C
5
A for 7 hours.
After the test. The battery should meet the criteria.
电池应不泄漏、不泄气、不
破裂、不起火和不爆炸。
No leak, no venting, no
rupture, no fire and no
explosion.
5.3.2 过放电保护
Over discharge
protection
电池在环境温度为 23±2℃条件下, 0.2C
5
A 放电至终
止电压后,外接 30Ω负载放电 7h,电池应符合判定标准。
Discharge the battery at 0.2 C
5
A to the cut-off voltage at
ambient temperature of 23±2 . And then discharge
the battery by connecting the battery to a load of 30Ω for
7 hours. After the test, the battery should meet the
criteria.
电池应不泄漏、不泄气、不
破裂、不起火和不爆炸。
No leak, no venting, no
rupture, no fire and no
explosion.
5.3.3
短路保护
Short-circuit
protection
电池 4.4 定充束后正负 80mΩ±20
电阻器短路 1h 后,电池应符合判定标准;将正负极断开,
电池以 1C
5
A 电流瞬时充电 5s 后用电压表测量电池电压,
应符合判定标准。
Charge the battery per section 4.4, and then short-circuit
the battery for 1 hour by connecting the positive and
电池应不泄漏、不泄气、不
破裂、不起火和不爆炸。瞬
时充电后,电池电压应不小
3.6V
No leak, no venting, no
rupture, no fire and no