Euphonix CO-600 Change-Over System For New Core DF66 Redundancy
21
Specications
Environmental
The CO-600 shall comply with the environmental operational and storage requirements 
as  summarized  in  Table  1:  Temperature,  Humidity,  Sound  Level,  and  Altitude 
Requirements.
Temperature, Humidity, Sound Level, and Altitude RequirementsTable 1 
Description Operating
Storage
Temperature 0° C 10 +35° C -40° C to +60° C
Temperature Gradient
(Non-condensing)
20° C/hr maximum 40° C-hr maximum
Humidity (Non-condensing)
Maximum Wet Bulb Temperature
20% to 85% RH
29° C
5% to 95% RH
40° C
Sound Level < 50 dBA 0 dBA
Altitude 0 to 10,000 ft above MSL
0 to 50,000 ft above MSL
at -40° C to 70° C
Altitude Gradient 1.5 kPa/min 8 kPa/min
Regulatory
The CO-600 is designed so as not to cause conducted or radiated interference to circuits 
internal  and external  to  the  unit  and  so that  it  is  not  susceptible  to signals  generated 
internally and externally to the unit.
Emissions 
The CO-600 meets the Class A emission limits requirements of both the FCC Part 15 and 
EN55103 Part 1 in environments E2 and E4.
Immunity
The CO-600  meets the  Class A immunity  requirements of  both the  FCC Part  15 and 
EN55103 Part 2 in environments E2 and E4.
Safety 
The CO-600 complies with European Standard EN60950 safety standard.
MADI
The CO-600 routes and  distributes MADI signals and conforms  to the recommended 
practice as documented in AES10-2003.