Installation manual
Euphonix CO-600 Change-Over System For New Core DF66 Redundancy
22
Latency
The  introduction  of  delay  in  the  MADI  signal  path  can  have  a  detrimental  effect  on 
the performance of the system.  Latency has been kept to a minimum - less than 500 
nanoseconds. 
Hot Swap
All  cards  are  capable  of  Hot-Swapping  without  interfering  with  the  operation  of  the 
other cards and components in the system.
Power
The power speciî‚¿cations for the PS-607 are listed below:
The PSUs is a universal AC Mains: AC: 100 to 240VAC, 50/60 Hz with PFC. 1. 
Input Current: 2A max per input. 2. 
Inrush current: 35 amps maximum3. 
+5 VDC  @ 25 amps, +3.3 VDC1 @ 30 amps, +12 VDC @ 1.5 amps, and -12 4. 
VDC @ 0.5 amps.
Dual AC Inlets for Mains redundancy.
5. 
Size: 3U cPCI 4 HP 200 watt PSUs. 6. 
Current shared operation with automatic ability to operate on one PS-6077. 