Specifications
R-1 Audio Deck Manual ©1999 Euphonix, Inc. Page 7
Rear Panel Connectors
IEEE 1394 ports (3) (IEEE 1394) The 1394 high speed communication protocol allows that any port
from any module can be connected to any port on any other module and that the
cables can “star” from one device, or can be daisy chained from device to device. The
recommended 1394 cable configuration for the R-1 Audio Deck is to connect a cable
from any of the three ports on the Audio Deck to any of the three ports on the Pilot
computer.
Word In (BNC) May be connected to a Word Clock source if Word Clock is the master
Sample Rate clock for the R-1 system. In the standard R-1 configuration where the
Studio Hub is a short distance from the deck, AES is recommended for synchronizing
the Audio Deck. In configurations where the Studio Hub is located remotely, the
Word Clock output from the Studio Hub may be used as the master Sample Rate clock,
and is then provided to this Audio Deck input.
Word Out (BNC) May be connected to the Word Clock input of a second chained Audio
Deck in a multi-deck R-1 system. When an external Word clock input is present this
connector provides a regenerated version of the input signal. When no external
Sample Rate source is detected this connector outputs the internally generated clock
signal. This later configuration, where the Audio Deck is the clock master, is not a
recommended mode.
AES In (XLR Female) Connected to one of the Studio Hub’s AES Sync Outputs in the
standard configuration. This is the recommended clock for the Audio Deck where the
Studio Hub is a short distance away.
MADI In (BNC) In the standard configuration this is connected to the Studio Hub MADI
output #1.
MADI Out 1 (BNC) Connected to the Studio Hub MADI #2 input in the standard
configuration. From 1 to 24 channels represents Audio Decks main channels of disk
playback and input monitoring. Channels 25 and 26, as well as 27 and 28 each
contain stereo monitor mixes, but the 25/26 pair are reduced in signal strength by –
12 dB.
MADI Out 2 (BNC) Same as MADI Out 1. Provided as a built-in Mult. Can be used with
MADI metering.
EXTERNAL SCSI
AD801
IN OUT
IEEE1394
MADI I/O
SYNC
IN OUT 1 OUT 2
AES
WORD