3/7 
Installation 
Set SW1 (A – D) if necessary (default = off) 
Set SW2 (DEV0 – 2) for an appropriate CAN frame address (default = off). 
Set SW2-4 (CAN-TERM) to terminate the CAN bus if required (default = off) 
Location of label switches on the C8702 module. 
The default IP address label is located on the “Coldfire” chip 
of the controller module and on the front panel of the module. 
While the MAC address is 
printed on a label here 
Can Buss Termination 
Can Buss Termination must be done on either the SY982 Sync or FC972 
Remote. Lack of termination or double termination may result in communication 
errors in the system. Typically, Can Termination is done on the FC972. 
Mode Switches 
Mode switch A is set to “ON” for use with Euphonix consoles. Mode switches B, 
C, & D are set to “OFF” 
Setting the frame ID 
Set DEV0, DEV1, & DEV2 to “ON.” 
FC972 Remote 