FC972 Remote 
4/7 
Can Buss Termination 
Can Buss Termination must be done on either the SY982 Sync or FC972 
Remote. Lack of termination or double termination may result in communication 
errors in the system. 
Software Setup 
Setting the IP address 
Each frame controller on a network must have a unique IP, subnet mask and 
gate way (if necessary). During configuration, FC972 modules are addressed as 
IP address: 192.168.0.150 (and upward), subnet: 255.255.255.0, gateway 
192.168.0.1. To change this, there are two principal methods, via RS232 or via 
network. 
IP address setup via RS232 
1.  Connect a PCs RS232 (COMx) via a 1:1 cable to the module and run 
a terminal program e.g. Hyperterminal or Minicom (115,200-8-N-1) 
and press ENTER : 
2. Select “2: Network configuration” and make the appropriate settings 
3. Select “4: Reboot” 
IP address setup via network 
1. Connect the FC972 via an Ethernet cross over cable to a PC. 
2. Change the network setting of the PC to the address room of the 
default IP address of the unit, subnet 255.255.0.0. 
Note: You will find the factory default IP address on a label at the 
controller module (see Installation). This address is valid only if the 
module is initialized to factory default settings using the front-panel INIT 
button. See Operation. 
FC972 Remote 