Update of the Controller Firmware 
The firmware for the FC-972 must be “burned” into the flash memory of the 
controller. Firmware comes as a zip file (compressed) which contains the 
firmware image. After download (contact Euphonix), the file must be unzipped 
(“extracted” on PC) saved to a known directory on the configuration PC. The 
image will be names “xyz.img” where “xyz” stands for the version number. 
Next, open the browser and type the IP address of the FC-972 into the URL 
window. Then go to the > MAINTENACE > SOFTWARE UPDATE page : 
Using the “SEARCH” button, select the appropriate image file from the file 
system of the PC. Then press the “START UPDATE” button. The controller will 
download the image file into its memory and will start the update process 
automatically. The process takes approximately 3~4 minutes. When finished the 
browser will show a message that the controller will now reboot. Afterwards you 
will see the initial web page of the FC-972. 
If for any reason (e.g. problems with java script in your actual browser version / 
configuration) this process is not successful you must reset the FC-972 by power 
cycling the frame or pressing the INIT button. Now you should open the browser 
again and connect with the FC-972 webserver. 
You must now enter the URL: 
 http://<C8702-IP>/standalone-update.html
Proceed with the image update as described above. When finished you will get a 
pop up saying the update was o.k. (it takes approx. 4 mins – be patient :-). 
Finally, you must reset the FC-972 manually either by power cycling the 
frame or pressing the INIT button, because the html file can not do this for 
you. 