Specifications
Modular I/O Configuration Guide98
Input Level Switches: Use the table below to set switches 1–4 to match the selected input level to 0 dBFS (full scale level). 
For Example: Set 0 dBFS = +24 dB to achieve -20 dBFS = +4 dBU = 0 VU.
Technical Specifications
Analog Level 
0 dBFS (full scale)
SW1 SW2 SW3 SW4
+15 dBU OFF OFF OFF OFF
+18 dBU OFF OFF OFF ON
+21 dBU OFF OFF ON OFF
+24 dBU OFF ON OFF OFF
+28 dBU ON OFF OFF OFF
To avoid damaging analog circuits, install a master sync source module in a red reserved slot before applying AC power.
Resolution 24 bit 
Sample Rate  32
–96 kHz 
Dynamic Range 
113 dB (RMS) 
116 dB (A) 
THD+N  <0.002% @ maximum input level 
Frequency Response 
48 kHz: 10 Hz – 20 kHz (
0,5 dB)
96 kHz: 10 Hz – 40 kHz (
0,5 dB)
Crosstalk 
>100 dB (1 kHz) 
>95 dB (20 kHz) 
>85dB (40 kHz) 
Maximum Input Level  15
–28 dBu @ 0dBFS 
Input Impedance  10 k, floating balanced 
Connector  XLR, 1:GND, 2:+, 3: -
Backplane Connector  DIN41612, 64-pin, a+b, male
Power Supply  +5 VDC 
Consumption   ~850 mA 
Dimensions  3 RU, 8 HP (2 slots)