RF Thermostat (Continued)
INITIAL SETUP
On/Off
Press and release the <PWR> button. If the thermostat is off, pressing and releasing <PWR> will turn the thermostat on
to the most recently selected working mode.
Setting the day of the week and time
With the thermostat off, press and hold the <T> button for 2 seconds or longer to initiate programming the time. ‘Time‘,
the ‘hour setting‘ and ‘AM/PM’ will flash.
Setting the hour function
1. Press and release the <UP> or <DOWN> button to increase or decrease the hour setting by 1 hour.
2. Press and hold the <UP> or <DOWN> button for 2 seconds or longer to increase or decrease the hour setting by
1 hour every 0.5 seconds. Press <OK> to accept and select the minute.
Setting the minute function
1. Press and release, or press and hold the <UP> or <DOWN> button to increase or decrease the minute setting by
1 minute similarly to the hour setting.
2. Press <OK> to accept and select the day of the week.
Setting the day of the week function
1. Press and release the <UP> or <DOWN> button to change the day of the week to the following or previous day.
Press and hold the <UP> or <DOWN> button for 2 seconds or longer to increase or decrease the day of the week
by 1 day every 0.5 seconds.
2. Press <OK> to complete setting.
The time and day of the week is now set.
The manual mode allows setting the temperature at any level.
Manual mode does not require that the time and day of the week are set.
With the thermostat on, press and release the <A/M> button until the word MANUAL appears on the LCD.
Adjusting the temperature
1. In manual mode, adjust the set temperature by pressing and releasing the <UP> and <DOWN> buttons. Press and
hold the <UP> and <DOWN> buttons to increase or decrease the temperature by 1°C every 0.5 seconds.
Note: The Thermostat will only send an ‘On’ command if the Set Temperature is above the Room Temperature.
When the Thermostat sends an ON command, the heater starts on Low Flame with the room fan in the OFF state.
- The Flame stays on the Low setting for 1.5 – 2 minutes and will then slowly ramp up to the highest setting over a
70 second period.
- The Room Fan will remain in the OFF state until the outlet temperature exceeds 50°C, at which point the Room Fan
will start and run at a speed dependent on the temperature difference between the Thermostat’s Set temperature
and Room temperature.
MANUAL MODE - THERMOSTAT
Derwent High Efficiency Gas Log Fire
16