Technical data

14
MIGNON
EN
For MCI versions:
According to the filter holder used, insert the removable fork in one of the two available
positions(Fig. 6).
• InMANUALmode(activatedbypressingselectionkey10Fig.1-MCI-handposition)rest
the filter holder bowl on the fork (8) and insert it to engage with the filter holder catch,
pushing it forwards until it comes into contact with the micro (7) to expel the ground coffee
(Fig. 9) from the spout (6). When the filter holder bowl is moved away, coffee dispensing
will stop.
• InTIMERmode(activatedbypressingtheselectionkey10Fig.1-MCI-clockposition),
the dispensing time for ground coffee can be set using the pull out dial next to the manual/
timer button, which needs to be turned to increase or reduce the amount of coffee ground
(Fig. 10).
This version of the appliance will continue to dispense coffee when the filter holder cup is
moved away, since dispensing will now depend on the set time.
WARNING
To avoid the blockage of the spout (6) hold the portafilter on the fork (8).
6.1 REGULATION OF THE GRIND
To adjust the grind, turn the adjustment (5) knob clockwise for more finely ground coffee and
counterclockwise for a coarser grind, as indicated on the knob itself (Fig. 5).