Installation Guide

Electrical parameters:
Model No.
Input Voltage
(V)
Input Frequency
(Hz)
Input Current
(A)
Input Watts
(W)
60
DLC-5020e
DLC-5000e
DLC-5040e
120 0.16 18
Product size:
Unit: mm
Installation steps:
STEP1:
Turn off the power before installation, remove the diffuser if exists and bulb if
necessary and remove the existing trim. Attach the relamping label to the
inside of recessed luminaire housing.
Figure 1
STEP5:
As shown in Figure 4
Push the LED retrofit trim into the recessed
light fixture, allowing the torsion springs to
pull the LED trim up into the recessed light
fixture. Continue to push the LED trim until
its outer edge is flush against the ceiling
surface.
STEP4:
Press both ends of the
springs and insert them
inside the lamp holder
bayonet as shown in Figure 3.
Figure4
Installation Instructions
The retrofit kit including LED Lamp , an installation instructionand field-applied label.
Please check these items when unpacking.
The units covered in this report are intended to retrofit Type IC or Non-IC covered ceiling
recessed luminaire with through-branch wiring marked “Max. 8 of 12 AWG conductors”
with instructions to remove the existing trim and diffuser.
WARNING - Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of
luminaires electrical systems. If not qualified, do not attempt to install. Contact a qualified
electrician.
WARNING
STEP2:
As shown in Figure 1
Twist the lamp base into the lamp holder.
STEP3:
As shown in Figure 2
Connected the lamp connector with lamp
base connector.
Figure2
B
18AWG
SOLID
WARNING - Risk of fire or electric shock. Install this kit only in luminaires that have the
construction features and dimensions shown in the photographs and/or drawings and where
the input rating of the retrofit kit does not exceed the input rating of the luminaire.
Do not make or alter any open holes in an enclosure of wiring or electrical components during
kit installation.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet
metal or other sharp objects.
Installers should not disconnect existing wires from lampholder terminals to make new
connections at lampholder terminals. Instead installers should cut existing lampholder leads away
from the lampholder and make new electrical connections to lampholder lead wires by employing
applicable connectors.
“MIN. LAMP COMPARTMENT DIMENSIONS 163(DIA) X 185(H) mm”or “MIN. LAMP COMPARTMENT
DIMENSIONS 130(DIA) X 180(H) mm”
“SUITABLE FOR DAMP LOCATIONS”
“WARNING –Risk of fire or electric shock. Do not alter, relocate, or remove wiring, lampholders,
power supply, or any other electrical component.
THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY
OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION.
THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS.
Dimension tolerance: ±1.5mm
191mm/7.52"
77mm/3.03"
Figure3
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cd
C0/180,92.0
UNIT:cd
C90/270,95.5
AVERAGE BEAM ANGLE(50%):93.8 DEG
0
100
200
300
400
500

Summary of content (1 pages)