USE, INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR BUILT-IN HOTPLATE Dear Customer Thank you for purchasing a Eurostyle Hotplate. Before we continue telling you about this hotplate, we cordially invite you to become part of the Eurostyle family by subscribing to ongoing information and invitations. You will find that the clean lines and modern look of your Eurostyle Hotplate blends perfectly with your kitchen décor. It is easy to use and performs to a high standard.
DESCRIPTION OF HOTPLATE ES60GFDBL ES700GFDBL ES90WGFDBL Natural 14.5 MJ/h 12.0 MJ/h 5.4 MJ/h 7.1 MJ/h 4.1 MJ/h 1 Ultra rapid gas burner/WOK 2 Rapid gas burner 3 Semirapid reduced gas burner 4 Semirapid gas burner 5 Auxiliary gas burner 6 Pan stands support 2F 7 Pan stands support 1F 8 Burner n° 2 control knob 9 Burner n° 5 control knob 10 Burner n° 1 control knob 11 Burner n° 3 control knob 12 Burner n° 4 control knob U-LPG 12.6 MJ/h 10.4 MJ/h 4.9 MJ/h 6.3 MJ/h 3.6 MJ/h Fig.
USE 1) BURNERS A diagram is screen-printed above each knob on the front panel. This diagram indicates to which burner the knob in question corresponds. After having opened the gas mains or gas bottle tap, light the burners as described below: - automatic electrical ignition Push and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position (large flame fig. 1), then depress the knob.
USE WARNINGS AND ADVICE FOR THE USER: use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The room must therefore be well ventilated by keeping the natural air vents clear (fig. A) and by activating the mechanical aeration device (suction hood or electric fan fig. B and fig. C). Intensive and lengthy use of the appliance may require additional ventilation.
USE WARNINGS AND ADVICE FOR THE USER: - Do not attempt to change the technical characteristics of the product because it can be dangerous. - If you decide longer use this appliance any more (or replace an old model), before disposing of it, make it inoperative in conformity with current law on the protection of health and the prevention of environmental pollution by making its dangerous parts harmless, especially for children who might play on an abandoned appliance.
CLEANING IMPORTANT: Always disconnect the appliance from the gas and electricity mains before carrying out any cleaning operation. 2) HOTPLATE Periodically wash the hot plate, the enamelled stell pan support, the enamelled burner caps “A”, “B” and “C” and the burner heads "T" (see fig. 3 and 3/A) with lukewarm soapy water. They should also be cleaned plugs "AC" and flame detection "TC" (see fig. 3). Clean them gently with a small nylon brush as shown (see fig. 3/B) and allow to dry fully.
INSTALLATION TECHNICAL INFORMATION FOR THE INSTALLER Check that the appliance is in a good condition after having removed the outer packaging and internal wrappings from around the various loose parts. In case of doubt, do not use the appliance and contact qualified personnel. Never leave the packaging materials (cardboard, bags, polystyrene foam, nails, etc.) within children’s reach since they could become potential sources of danger.
INSTALLATION 4) FIXING THE HOTPLATE fastening hooks “G” (fig. 6). - When the appliance is installed so that the base can be touched, we recommend fitting a protecting shield. This shield must be at least 70 mm below the base of the bench top (fig. 4). Timber or other suitable material may be used provided it is capable of withstanding the appliance temperatures. Ensure that the supply connection point is accessible with the appliance installed. To facilitate shield may need to be removable.
INSTALLATION The transition piece on the supply side of the regulator must be provided by the installer. 5) GAS CONNECTION The gas connection is located in the rear and on the right hand underside of these appliances: 24 mm (mod:ES60GFDBL), 144 mm (mod:ES700GFDBL), 230 mm (mod: ES90WGFDBL). There are two ways to carry out the connection to the main gas line: A. The hotplate can be connected with rigid pipe as specified in AS/NZS 5601. B.
INSTALLATION 6) ELECTRICAL CONNECTION and lead to dangerous overheating. When the appliance is connected straight to the electricity main: - Install an omnipolar circuit-breaker between the appliance and the electricity main. This circuitbreaker should be sized according to the load rating of the appliance and possess a minimum 3 mm gap between its contacts. IMPORTANT: the appliance must be installed following the manufacturer's instructions.
ADJUSTMENTS Always disconnect the appliance from the electricity main before making any adjustments. All seals must be replaced by the technician at the end of any adjustments or regulations. Our burners do not require primary air adjustment. a) Data Label The Data Label is located on the underside of the hotplate. A duplicate Data Label is supplied to adhere in an accessible area next to the hotplate.
CONVERSIONS 8) UNIVERSAL LP GAS TO NATURAL GAS CONVERSION PROCEDURE 9) NATURAL GAS TO UNIVERSAL LP GAS CONVERSION PROCEDURE Appliance models: Gas stainless steel hotplate models: Appliance models: Gas stainless steel hotplate models: ES60GFDBL ES700GFDBL ES90WGFDBL ES60GFDBL ES700GFDBL ES90WGFDBL 4 Burners 5 Burners 5 Burners 4 Burners 5 Burners 5 Burners 1. Remove each burner cap and burner skirt. 2.
CONVERSIONS and affix the label corresponding to the new gas regulation on the appliance instead of the already existing one. This label is supplied in the packet containing the spare injectors. The envelope with the injectors and the labels can be included in the kit, or at disposal to the authorised Customer Care Department . For the sake of convenience, the nominal rate chart also lists the heat inputs of the burners, the diameter of the injectors and the working pressures of the various types of gas.
SERVICING CABLE TYPES AND SECTIONS TYPE OF HOTPLATE Gas hotplate TYPE OF CABLE SINGLE - PHASE POWER SUPPLY H05 RR - F Section 3 x 0.75 mm2 ATTENTION!!! If the power supply cable is replaced, the installer should leave the ground wire (B) longer than the phase conductors (fig. 11) and comply with the recommendations given in paragraph 6.
TECHNICAL ASSISTANCE AND SPARE PARTS Before leaving the factory, this appliance will have been tested and regulated by expert and specialised personnel in order to guarantee the best performances. Any repairs or adjustments which may be subsequently required may only be carried out by qualified personnel with the utmost care and attention.