EURO User Manual Contents Introduction Using EURO Panel with Code or Tag Intelligent Setting Silencing the Alarm Setting Individual Areas Chime Facility Omitting Inputs Keypad Hold Up/Personal Attack Manager Menu Omitting 24 hr Inputs Changing Date & Time Change/Add Codes or Tags Adding Wireless Keyfobs Deleting Codes, Tags and Keyfobs Review History Log SMS Phonebook Walk Testing Detectors SMS Messaging System Testing your Sounder Dial Out Menu Allow Engineer Menu Block Remote Set Perform Anti-Code Reset
EURO User Manual The Euro Keypad Note: For your security, the keypad becomes disabled for 90 seconds after 30 incorrect key-presses. It will subsequently be disabled again after 7 further incorrect key-presses. Once a correct code has been registered, the keypad is returned to normal operation.
EURO User Manual Using Proximity Tags Your EURO system may have been enabled for use with proximity tokens, or ‘Tags’.* If you have Tag Readers installed then simply hold your Tag against the ‘Tag’ logo. When using the keypads, hold your Tag to the area shown left. When your Tag has been accepted there will be an acknowledgement ‘beep’. You can use your Tag in place of a pin code for all operations of the alarm system, i.e. setting, unsetting, and entering the Manager and User Menus.
EURO User Manual Using Keyfobs The Wireless Key Fob allows quick, easy and control of your alarm system. Press the closed padlock to set the system Press the open padlock to unset the system The functionality of the buttons is fully programmable, and it is useful to keep a record in the table below to remind you how your fob has been configured. + I II I + II I + II + Note: Not all buttons may be active on your fob.
EURO User Manual Warning Indications All setting points (Keypads or Tag Readers) have LEDs to clearly indicate what is happening. Alert Alarm Tamper Fault Unset The ‘Alert’ LED will flash if there is information available to you. Enter your code to see the information. After a code has been entered, one of the following LEDs will light: Alarm, tamper or fault. The relevant detail of the problem will be shown on the display.
EURO User Manual Security Checks Before you set your system: You must ensure all doors and windows are securely closed and any pets or people are excluded from areas protected by movement sensors.
EURO User Manual Leaving the Building EURO Time: 15:02 If you are leaving the building, go to your keypad and key in your PIN code, or present your tag. The Exit Tone Starts The appropriate area (ABCD) keys will illuminate. (If flexi-set is enabled you will be able to choose which areas you set, see page 15) Leave by agreed Exit Route SETTING [009] OFFICE Close and Lock the Final Exit Door Finally, press the ‘Push to Set’ button (if fitted) that is mounted externally by the final exit door.
EURO User Manual Simple Setting It is also possible to set the EURO without using your PIN code or Tag. EURO Time: 13:36 When your system is unset, press the ‘YES’ key, and then select the area you wish to set. For example, to set area C: Press ‘YES’, then Press ‘C’ Setting Area C [15] The exit procedure will start. “beep – beep – beep – “ EURO Area C EURO is now Set Please note that when using the ‘simple set’ facility, the user who initiated the set cannot be logged.
EURO User Manual Entering the Building To enter the building you must use the agreed entry route and go straight to the keypad. ENTRY TIME [020] The Entry Tone will be sounding “beep – beep – beep –“ ENTRY TIME [010] ** Key in your PIN code, or present your tag. The Entry Tone will cease To indicate that the system has unset, the unset LED will illuminate for five seconds.
EURO User Manual Quick Adding of a New Tag If during the unset mode you present a tag to the system which is not recognised, you will be asked if you would like to add it as a valid user. Unknown Tag Add new user? Press ‘YES’ (Press ‘NO’ to cancel and return to day mode) Enter a managers Code or tag [ ] A valid manager code must be added to authorise the addition of the new tag.
EURO User Manual Using an External Proximity Reader Setting your EURO panel with the External Proximity Reader Present a valid tag to the reader and then remove it. The GREEN LED will come on. Present the same tag to the reader, and then remove it. The exit time will start on the control panel. The RED LED may be programmed to illuminate under certain actions (for example when the system is set).
EURO User Manual Using an External Proximity Reader Setting your EURO panel with the Internal Proximity Reader Present a valid tag to the reader and then remove it. The GREEN padlock LED will come on for 5 seconds to indicate that the panel is setting. An exit tone will be generated during the exit prodedure, and a confirmation beep will sound 5 seconds after completion of setting. Unsetting your EURO panel with the Internal Proximity Reader Present a valid tag to the reader and then remove it.
EURO User Manual Intelligent Set If you wish to set your EURO panel and stay in the building (e.g. set the alarm at night), the EURO’s intelligent operating system will realise which level of security you require and will set only part of the system. You will NOT need to press a Push-to-Set button if you set only part of a system. If intelligent set is not installed on your system, you may part set the system as described on pages 14-15.
EURO User Manual Codes with Flexi-Set Euro 46 Time 15:20 Sometimes your security needs will be a little more complex and you will need to use the A B C D keys. Your installer can also give names to all four of the A B C D areas, so that you can easily identify them.
EURO User Manual Codes with Flexi-Set SET AREAS [ABCD] For greater flexibility in setting parts of your system, you can make a choice at the keypad. Key in your PIN code or present your Tag. If you do not wish to set all the areas assigned to your PIN code/tag, simply select the areas you wish to Set by pressing the relevant A B C D key(s). To change your mind, press the relevant A B C D key(s) again.
EURO User Manual Flexi-Unset EURO Time 15:25 When EURO is already set and you wish to unset: Key in your PIN code or present your tag. If entry timer has started: All areas for which the tag or PIN code is valid will be unset. Any areas set for which the code is not valid will remain set, e.g. if A and B are set: If a tag valid for area ‘A’ only is presented, then area A will be unset, leaving B set. If a tag valid for areas ‘A B’ is presented, both A & B will be unset.
EURO User Manual Flexi-UnSet If your codes have been set up with Flexi-Unset enabled, you will always have a choice of what areas you would like to set or unset, regardless of whether the entry timer is running or not – providing you have a code valid for the relevant areas. This function can only be enabled by your alarm installing company, and will not be permitted if your system is designed to comply with clause 6.4.5 of BS8243:2010. Ask your installer for further details.
EURO User Manual Deliberately omitting an Input when leaving the Building In a domestic setting you may wish to ignore a window you have deliberately left open in the summer time. There may be another fault on the system which you want to ignore when you set the system. Enter your PIN code or present your tag. The display will ask if you wish to set with the fault. Set with Fault? Bedroom Window To omit the fault, Press ‘YES’ (or ‘NO’ if you do not wish to omit). The system will then set as normal.
EURO User Manual Deliberately omitting an Input when leaving the Building OMIT INPUT? At some time you may wish to isolate a detector if a room is occupied. Enter your PIN code or tag. While the exit tone is sounding press the ‘YES’ key. When the ‘OMIT INPUT’ menu is displayed: Key in the number of the input you wish to omit and press ‘YES’. (Always use a leading zero, eg 02 is input 2) If it has been accepted it will be displayed on the screen. Repeat for any other inputs that need to be omitted.
EURO User Manual Silencing Alarms If an alarm tone sounds, the alert LED will flash: Just key in your PIN code or Present your tag. The Alarm will stop sounding Alarm Silenced Low Volts The display will indicate the why the alarm has activated. Press the ‘YES’ Key Call Engineer Low Volts EURO will advise you on any action that is needed. If the ‘Alert’ LED indication remains lit, there is additional information available. Enter your PIN or present your tag to view.
EURO User Manual Engineer Reset Quote G19867 Anti-Code Needed When an alarm has been cancelled and the Police have been notified by the Alarm Receiving Centre (ARC), you will see the screen shown left when you try to use the system. It is usually necessary for an engineer from your installation company to check the installation and reset the system for further use.
EURO User Manual The Chime Facility The ‘C’ key can be used to select the ‘chime’ facility while the system is Unset. For example, you may wish to be alerted if someone enters through a particular door during the day. Simply press the ‘C’ key. Euro 46 Time: 15:31 Euro 46 Time: 15:32 The display will show a ‘C’ c Now if the door opens you will be alerted by the ‘chime’ tone. To cancel the ‘Chime’ function, simply press ‘C’ again. Note: This is only operative on detectors programmed for this purpose.
EURO User Manual Keypad Hold-Up Euro 46 Time 15:40 If you need to summon personal assistance in an emergency, EURO allows you to do so. Simply press the ‘1’ and ‘7’ keys at the same time. Or you may have a wireless keyfob which is enabled for raising an emergency alarm. Usually this is achieved by holding down buttons I & II together. To reset: Enter your PIN code or present your Tag. Note This facility is only available if it has been enabled by your alarm installer.
EURO User Manual Manager Menu Euro 46 Time: 15:45 The manager menu is accessed by pressing ‘D’ and then keying in your Manager PIN code.
EURO User Manual Set Date and Time SET DATE & TIME? YEAR (00-99) [06] Press ‘YES’ (Press ‘NO’ to move to the next menu) Enter Year (eg 06=2006) Press ‘YES’ MONTH (1-12) [08] Enter Month Press ‘YES’ DAY (1-31) [12] Enter Day Press ‘YES’ HOURS (00-23) [13] Enter Hours (24 hour clock) Press ‘YES’ MINUTES (0-59) [45] Enter Minutes Press ‘YES’ DST Adjust? Yes [1] Use B and D keys to select whether you wish Euro to automatically update the clock for Daylight Savings Time.
EURO User Manual Omit Inputs Omit Day Al[--] Some of your doors may rarely be used (e.g fire doors) and your system may be designed such that if they are opened your panel will generate an alarm, even if the panel is unset. If you need to open these doors you can omit them from the system as shown below. (Only inputs of ‘tamper’ and ‘day alarm’ type can be omitted this way, as set up by your alarm installing company). Omit Day Al[06] FIRE DOORS Enter the input number you wish to omit.
EURO User Manual Adding PIN Codes or Tags A record should be kept as shown on Page 48 CHANGE CODES? Press ‘YES’ (Press ‘NO’ to move to the next Menu) Add New User? Press ‘YES’ (Press ‘NO’ to delete or change an existing user) Go to the next page to learn how to add new users to the Euro System. Delete/Change User? Press ‘YES’ (Press ‘NO’ to program the Master Manager Code) Turn to page 35 to learn how to delete or edit users.
EURO User Manual Adding PIN Codes or Tags Empty [004] EURO identifies each user by a different ‘User Number’. Eg ‘John’ would be user 01 – ‘Jane’ would be user 02 etc. Now key in the ‘User Number’ whose PIN code/Tag you wish to add or change. Only available slots are shown. Press ‘YES’ Key in the new 4,5 or 6 digit PIN code you require or present the new Tag. ENTER USER CODE [****] To delete a code or Tag press ‘C’.
EURO User Manual Adding PIN Codes or Tags User Type (User) [0] Choose the level of authority the user is allowed. User – cannot access Manager Menu. Manager – can use Manager Menu. (Use ‘B & D’ keys to make your choice). Press ‘YES’ User Areas [A ] Using the A B C D keys, choose the areas you wish to be controlled by the user.
EURO User Manual Adding PIN Codes or Tags Flexi Set Yes Flexi Set No [1] [0] Flexi Set Yes [1] Flexi-Set gives you the opportunity to choose the areas you require to set when you use your PIN code or Tag. If you do not choose Flexi-Set your Code/Tag will simply set the areas assigned without offering you the opportunity to choose.
EURO User Manual Adding PIN Codes or Tags Using the numeric keys, you can enter a user name, similar to typing a text message on a mobile phone. Use ‘0’ key for space. The A B C D keys on the keypad are used as follows: ‘A’ – capital letters ‘B’ – moves cursor left ‘C’ – Clears Character, creates a space ‘D’ – Cursor moves right e.g. to write ‘John’ simply press the ‘5’ key once [‘J’ will appear] ‘D’ move cursor right ‘6’ key three times The predictive text library selects John, press ‘YES’ to accept.
Enforcer User Manual Adding Key Fobs Empty [003] Key in the ‘User Number’ whose PIN code/Tag you wish to add or change. Press ‘YES’ Enter User Code [****] Press any button on the key fob. Stars will appear in the square brackets. To delete a key fob press ‘C’. Press ‘YES’ User Name _ You can now enter a name for the user, as per the instructions on page 31. Press ‘YES’ Select Button Lock [1] You will now be prompted to configure the buttons on the key fob.
Enforcer User Manual Adding Key Fobs Button 1 Button 5 Button 2 Button 6 + Button 3 Button 4 I Button 7 II Button 8 I I II + II + + After you have selected which button to programme, press ‘YES’. Button Action Show Status [1] There are 6 actions that can be assigned to the individual buttons, use the the ‘B’ and ‘D’ keys to toggle between the different options, and then press ‘YES’.
Enforcer User Manual Adding Key Fobs No Action Show Status Set Area Unset Any Area Latch Output Timed Output User Controls [A ] Use the ABCD keys to enter which areas you would like the key fob to control. Press ‘YES’. Output [xx] Fob Output 1 Output ON Time [030] Use the B & D keys to choose which output you wish to be triggered by the designated fob button. Press ‘YES’. Use the number keys to enter a time in seconds for which you wish the input to remain live. Press ‘YES’.
EURO User Manual Adding PIN Codes or Tags Delete/Change User? [005] To edit or delete a user, use the B and D keys to select the user number from the list. The user type (code, keyfob or tag will displayed along with each user’s name for easy reference). Press ‘YES’ Delete User? Change User? If you wish to completely delete the user, then press ‘YES’ or press ‘NO’ if you wish to edit the user details.
EURO User Manual Review History Log REVIEW LOG? Press ‘YES’ (P ress ‘NO’ to move to the next menu) Panel Log? Press ‘YES’ To advance through the logs: Date & Time Press ‘D’ For added information: Press ‘C’ To move backward to previous events: Press ‘B’ To stop review: Press ‘NO’ To move to the next menu, press ‘NO’ again. Note: If an access control facility is in use, a separate dedicated access control event log is recorded.
EURO User Manual SMS Phone Book PHONEBOOK? Press ‘YES’ (Press ‘NO’ to move to the next Menu) SMS Numbers [1] Use the ‘D’ key to scroll to which SMS telephone number you wish to change (1-4). Press ‘YES’ Mobile No. 07 951_ Using the numeric keys, type in the new telephone number (do not leave any spaces). You can move the cursor back with the ‘B’ key and forward with the ‘D’ key. Use the ‘C’ key to delete a character.
EURO User Manual Testing your System WALK TEST? Press ‘YES’ (Press ‘NO’ to move to the next Menu) Choose the area(s) you wish to test by pressing the appropriate ABCD keys. Walk Test Zone Front Door Press ‘YES’ All detectors waiting to be tested will scroll in the display. Walk around the building and activate all of the detectors. The system will ‘chime’ each time a detector responds.
EURO User Manual Start CHC SMS Update Your system may have been configured to send messages to a mobile telephone. If so, the system will call the appropriate messaging bureau and forward the message to your mobile telephone whenever an event occurs that is important to you. Message calls are charged at the normal network rate current at the time of the call.
EURO User Manual Test CHC Communications It is recommended that this test is only undertaken under the supervision of your alarm installation engineer.
EURO User Manual Dial Out Menu DIAL OUT MENU? Your alarm system may be configured so that you can control the system via a PC. If you wish to continue… Press ‘YES’ (Press ‘NO’ to move to the next menu) Select PC to dial [1] Use the ‘D’ key to select the required PC from the list (1-4) and Press ‘Yes’. Use the ‘D’ key to select the operation you require: Data to PC: View the system history on your PC, where it can be searched and printed.
EURO User Manual Allow Engineer Menu ALLOW ENGINEER MENU? When your alarm installation engineer comes to your premises for a maintenance visit or to correct a fault after an alarm he will require access to the programming of the system. Press ‘YES’ Use ‘B & D’ keys to make your choice. Press ‘YES’ After the engineer has finished on site, you may return this setting to ‘NO’.
EURO User Manual Block Remote Set BLOCK REMOTE SET? Your alarm system may be configured so that your alarm installation company or company manager can set or unset the system remotely via PC. Should you wish to block this access you can do so through this menu. Press ‘YES’ Make your choice with the ‘B’ and ‘D’ keys. Block UDL BLOCK UDL? If you wish that your alarm company can only dial into your system with their PC whilst their engineer is on site, this can be set up through the ‘Block UDL’ menu.
EURO User Manual Menu Exit EXIT MANAGER MENU? To exit from Manager Menu and return to normal mode. Press ‘YES’ If you wish to select any of the Manager Menu items again press the ‘NO’ key until your choice is displayed (see page 24).
EURO User Manual Troubleshooting Help with Setting your System If when you key in your PIN code (or present your Tag) a warning tone sounds and the fault LED comes on, the keypad display will show the nature of the problem. UNABLE TO SET BACK DOOR An appropriate A B C D key will flash to indicate within which area the problem exists. The tone will cease after about 10 seconds. Press the NO key The system will remain unset, so you can resolve the problem.
EURO User Manual Troubleshooting Problems when leaving the Building If when you have closed the final exit door (and pushed the ‘Push to Set’ button if fitted), the exit tone continues to sound an interrupted tone… “beep – beep – beep – “ You have probably left a protected door on the exit route open. Return to the keypad and note the message on the display. EXIT VIA HALLWAY Stop the setting procedure with your PIN code, or Tag. Close the open door Now commence the setting procedure again (see page 7).
EURO User Manual Service Information We are sure that you will be delighted with your Euro Alarm installation. For your personal reference here is a record of the relevant service information. External set/unset readers and access control readers meet the requirements of environmental class 4.
EURO User Manual User Codes Warning: This information should be removed from the manual and stored in a secure location. Photocopy this page if you have more users.
EURO User Manual Disclaimer EURO includes the facility to send electronic signals to an Alarm Receiving Centre (ARC), and also to send SMS text messages to mobile telephones. Alarm, etc. signals may be transmitted via a PSTN link, using a variety of formats, to suitable receiving equipment located at the premises of an independently operated Alarm Receiving Centre.
No Descriptions A B C D 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 Page 50 0 1
Page 51
Page 52