Specifications

7 - INSTALLING THE CONDITIONER
Conditioner housed inside the cellar:
There are 2 methods for attaching the hot air extraction piping:
- Attaching the piping directly to the aesthetic front panel:
- Position and screw, using a Hex wrench (supplied), the two supplied anges* onto the aesthetic front panel (1).
- Fit together the reducer (2).
- Position the air extraction piping (standard piping, 160 mm in diameter, not supplied) (3).
- Attaching the piping directly to the conditioner housing (the extraction piping passes through the wall):
If using this method, you must not use the exible ducting supplied with the
conditioner.
- Fit the reducer* directly onto the mounting frame through the wall (1).
- Position the air extraction piping (standard piping, 160 mm in diameter, not supplied) (2) (3).
For this type of fitting, it is necessary to ensure sealing around the piping.
*Consult your EuroCave distributor
IV- Discharging condensate
The conditioner was designed to allow condensate to be discharged (discharge pipe located under the
conditioner’s housing) either inside the cellar
, if the humidity level is too low, or outside the cellar.
Simply pass the pipes through the wall to discharge the condensate into the room next to the conditioner
housing.
Ensure that the piping is not cramped.
(1) (2) (3)
(1) (2) (3)
13