IN1042 Installation Instructions For HARMONY 1&3 STANFORD 80 Wood and Multifuel Stoves This manual must be used in conjunction with document IN1173 The Wood and Multifuel Chimney and Installation Guide, This Manual Must Always Be Available To The Stove Operator Part No. Model Name Serial Number © EUROHEAT DISTRIBUTORS (H.B.S) LTD.
The Model Range Explained Nestor Martin and Euroheat insist on progressive development to produce products which are market leading. Our aims are to produce stoves with the latest innovations, user friendly operation and highly efficient for lower cost operation. This operation manual offers user information for the range of HARMONY 1, HARMONY 3, AND STANFORD 80 In some cases you find references in this document to the model size rather than the models exterior design. There are two sizes of appliances.
IMPORTANT . The installation of this appliance must comply with all local regulations, including those referring to national and European Standards before it can be operated. The stove is not suitable for a shared flue.
Technical Details Model Name Model Number Heat Output Weight KG Nominal Wood Flue Draught Nominal Heat Output Flue Gas Mass Flow g/s Flue Gas Temperature Down Stream of Flue Spigot deg C Harmony 1 39692 8kW 155 11pa 7.6 365 Harmony 3 39696 16kW 213 10pa 14.6 365 Stanford 80 39962 8kW 155 11pa 7.
Changing to Rear Flue Connection 1. Remove flue spigot from top of stove and the flue spigot protector. 2. Remove flue blanking plate from rear of stove. 3. Fit the blanking plate to top of stove with the blanking plate protector. This protection plate is supplied with the appliance normally located in the ash pan of new models. 4. Fit flue spigot to rear of stove. Do not fit the flue spigot protector.
Fireplace Design Do not be tempted to fit the stove into an unsuitable fireplace. Beyond the requirements of Building Regulations and access to facilitate servicing the stove, providing a setting which will compliment a stove is not a luxury, it is the practicality of making the most of an investment. A good builder or fireplace specialist will be able to transform even the most utilitarian of fireplaces.
Minimum Installation Clearances From Combustible Materials. In all installations surrounding flammable materials must not exceed 65°C. Minimum clearance from flammable materials A B C D E A 300mm At least 250mm At least 300mm At least 300mm At least 250mm At least B E D C Curtains and furnishings should be a minimum of 1m from the stove or the surface temperature must not exceed 65°C. From Non-combustible Materials.
Removing Internal Protection Castings and Grate Step 1 Removing Top Baffles Lift the right hand baffle upwards, lifting the rear more than the front. Move the baffle towards the stove back to allow the front edge to clear the supporting ledge and pull forward. The left baffle removes similarly. To replace the baffles reverse the procedure, ensuring the front edges of the baffles are pulled to the front of the stove and the baffles are as close together as possible.
Step 4 Removing Riddling Links Remove or loosen rear heat shield Remove screw “A” Remove riddling link bar “B” Remove screws “C” and riddler guide seals. C A B Step 6 Removing Grate Frame Remove grate frame. Lift rear edge of grate frame. Lift frame move to the right through side door then remove through front door. Step 5 Removing Grate Lift front of grate remove through front door. © EUROHEAT DISTRIBUTORS (H.B.S) LTD.
Draught Requirements inches 0.06 0.04 Euroheat can supply the flue measurement gauges order number MS026. .09 .08 .07 1.0 .9 .8 .06 .7 .05 .6 Minimum firing rate Maximum firing rate Note this is not a water gauge used to measure gas pressure. .5 .04 .03 .4 .3 .2 .02 .01 IN. OF WATER DRA FT OR PRESSU RE - HIGH RAN GE 0.02 Flue draught measured with the air wash vent fully open and all other air supplies to the fire closed. RE - LOW RANGE FT OR PRESSU IN. OF WATER DRA millimetres .1 .
Commissioning Check List X Mark box when completed Inspect the door and glass seals and ensure all handle latches are adjusted correctly, procedure in the operating instructions. Check baffles are installed correctly and that the riddling mechanism is operating. Ensure that the fire responds to the operation of the controls and that there are no visible emissions of the combustion products into the room. Check the flue draught is within the parameters within these instructions.