INSTALLATION
Installing/Replacing the lamp
DANGERTOLIFE!
Onlyinstallthelampwiththedeviceswitchedoff!
Unplugfrommainsbefore!
Thelamphastobereplacedwhenitisdamaged
ordeformedduetotheheat!
CAUTION!
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 15 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one PAR-38 lamp with up to max. 80 W. The illuminant is installed or replaced
from the front.
Procedure:
Step 1: If replacing the lamp, remove the old lamp from the spot.
Step 2: Screw the new 230 V/80 W PAR-38 E-27 lamp into the lamp socket.
Keep exchanged lamp in a protective container and remove accordingly.
Do not operate this device with opened housing cover!
Overhead rigging
DANGER TO LIFE!
Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.