User manual

00042012.DOC, Version 1.1
33/33
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
s
ediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Always disconnect from the mains when the device is not in use or before cleaning it.
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
Clean the front glass every two weeks from dust and smoke fluid residues.
There are no servicable parts inside the device. Never open the housing! Maintenance and service
operations are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuseholder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
8. TECHNICAL SPECIFICATIONS
Power supply: 115/230 V AC, 50/60 Hz ~
Power consumption: 30 W
DMX control channels: 9
DMX512 connection: 3-pin XLR
MCU-connection: 9-pin SUB-D
Maximum optical power: 20 mW
Laser classification: 3B
Wavelength: 650/532 nm
Laser-modules: Red 20 mW, green 10 mW
Beam: approx. 12 mm / 1 mrad
Scanning speed: 2,000 pps
Dimensions without bracket (LxWxH): 335 x 270 x 135 mm
Weight: 5.5 kg
Fuse: F 1 A, 250 V
Accessory:
EUROLITE NOT-01 laser interlock No. 51741435
Extension cable 10m for EUROLITE NOT01 No. 51741438
Please note: Every information is subject to change without prior notice. 07.01.2010 ©