User manual

00107423, Version 1.1
25/32
Connection between devices
On the rear panel, there is an IEC socket (Power Out). Connect the output with the input of the next fixture
until all fixtures are connected.
Attention: It is recommended to renew the connection with the power mains after every 8 devices.
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown Live L
Blue Neutral N
Yellow/Green Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the device to the mains, the EUROLITE LED BAR-12/BAR-6 QCL RGBA Bar starts
running.
The display lights up and you can choose the desired mode via the buttons MODE, ENTER, UP and DOWN.
The device has two operating modes. It can be operated in stand-alone mode via the control board or in
DMX-controlled mode via any commercial DMX controller.
Stand-alone mode
In the stand-alone mode, the device can be used without controller.
Disconnect the device from the controller. Please refer to further instructions under Control Board.
Control Board
The Control Board offers several features: you can easily set the starting address, run the pre-programmed
program or select a DMX channel mode.
Enter the menu by pressing the MODE-button. Browse through the menu by
pressing UP or DOWN. Press ENTER in order to select the desired menu. You
can change the selection by pressing UP or DOWN. Press ENTER in order to
confirm. You can leave every mode by pressing MODE. The functions provided
are described in the following sections.
MODE UP DOWN ENTER